Why the study?
Does the absence of prior ICD shocks predict a lower incidence of shocks after elective generator exchange in ICD patients?
Does the absence of prior ICD shocks predict a lower incidence of shocks after elective generator exchange in ICD patients?
Even among patients who do not experience ICD shocks during their first battery life, the incidence of shocks at 5 years following generator exchange remains clinically significant (>25%), supporting informed shared decision-making at the time of replacement.
Absence of prior shocks was associated with lower post-exchange risk; supports shared decision-making at replacement but leaves open practice change.
BACKGROUND: A significant number of implantable cardioverter-defibrillator (ICD) patients do not experience shocks after ICD implant. Elective generator exchange (GE) has been associated with increased risk of infection and ICD lead failure. There is a paucity of contemporary data reporting on shock incidence with replacement devices. METHODS AND RESULTS: Patients undergoing elective GE (n=24 203) who transmit data remotely via a remote monitoring system were analyzed to determine the incidence of ICD shocks after GE. A total of 16 230 patients (67%) did not experience a shock with the first ICD (group A), and 7973 (33%) received at least 1 shock (group B). Patients in group A were older (71.3 versus 68.8 years, P<0.001) and more often female (71% versus 77% male, P<0.001). Over an average follow-up of 1.9±1.2 years after GE, the proportion of patients with shocks and risk of ICD shocks was lower for those who did not receive a shock during the first battery life (group A: 9.9% versus 27.7%, hazard ratio 0.36, 95% CI 0.34 to 0.38, P<0.001). The cumulative rate of ICD shocks at 5 years after GE was 25.7% in group A and 51.1% in group B. CONCLUSIONS: In this large cohort of ICD patients implanted across the United States, two thirds did not receive ICD shock therapy prior to GE. The occurrence of ICD shocks prior to GE is an important predictor of shocks after GE; however, even among those without shocks during first battery life, the incidence of shocks at 5 years following GE is >25%. These data should support informed decision making for patients and physicians at the time of ICD generator end of service.
No takes yet. Share an insight, caveat, or question.
Merchant et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: