Key result
ICD generator exchange patients report significantly worse physical health compared to emotional well-being.
Why the study?
Little was known about health status and quality of life following implantable cardioverter-defibrillator generator exchange.
Observational (n=63)
Yes
Absolute Event Rate: 62.3% vs 81.4%
p-value: p=<0.001
Patients undergoing ICD generator exchange maintain stable quality of life, but physical health is often impaired by comorbidities, and most subsequent deaths are non-arrhythmic, highlighting the need for shared decision-making.
BACKGROUND: Little is known about health status and quality of life (QoL) after implantable cardioverter-defibrillator (ICD) generator exchange (GE). METHODS: We prospectively followed patients undergoing first-time ICD GE. Serial assessments of health status were performed by administering the 36-Item Short Form Survey (SF-36). RESULTS: < 0.001 for each comparison). Physical health scores were significantly worse among those with medical comorbidities including diabetes, chronic obstructive pulmonary disease and atrial fibrillation. Mean follow-up was 1.6 ± 0.5 years after GE. Overall SF-36 scores remained stable across all domains during follow-up. Survival at 3 years post-GE was estimated at 80%. Five patients died during follow-up and most deaths were adjudicated as non-arrhythmic in origin. Four patients experienced appropriate ICD shocks after GE, three of whom had LVEF which remains impaired LVEF (i.e., < 35%) at the time of GE. CONCLUSION: Patients undergoing ICD GE have significantly worse physical health compared to emotional/social well-being, which is associated with the presence of medical comorbidities. In terms of clinical outcomes, the incidence of appropriate shocks after GE among those with improvement in LVEF is very low, and most deaths post-procedure appear to be non-arrhythmic in origin. These data represent an attempt to more fully characterize the spectrum of QoL and clinical outcomes after GE.
No takes yet. Share an insight, caveat, or question.
Merchant et al. (2021) conducted an observational in Implantable cardioverter-defibrillator (ICD) generator exchange (n=63). ICD generator exchange was evaluated on SF-36 physical functioning score compared to emotional well-being score (p=<0.001). Patients undergoing implantable cardioverter-defibrillator generator exchange had significantly worse physical health scores compared to emotional and social well-being scores.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: