The study demonstrates that synchronization in isorhythmic A-V dissociation is caused by retrograde atrial capture by an A-V junctional rhythm.
Answers are grounded in this paper and cite their sources.
Retrograde capture explains synchronization in isorhythmic AV dissociation; extends mechanistic insight but remains hypothesis-generating.
We studied 11 patients with spontaneous isorhythmic atrioventricular (A-V) dissociation occurring during cardiac surgery. The period of synchronization or accrochage was shown to result from retrograde capture of the atria by an A-V junctional rhythm. The P wave in leads II, III, and aV F was biphasic (–, +) during the period of synchronization, with the initial negative portion of the P wave or the entire P wave often buried within the QRS complex. It was concluded that isorhythmic A-V dissociation occurs only during the period when the rhythm alternates between an atrial rhythm and an A-V junctional rhythm and results when either the dominant pacemaker slows or the latent pacemaker accelerates.
No takes yet. Share an insight, caveat, or question.
Waldo et al. (1968) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: