Why the study?
Does 4D flow cardiac magnetic resonance improve the identification of the cause of bioprosthetic pulmonary valve dysfunction compared to transthoracic echocardiogram in a patient with repaired tetralogy of Fallot?
Does 4D flow cardiac magnetic resonance improve the identification of the cause of bioprosthetic pulmonary valve dysfunction compared to transthoracic echocardiogram in a patient with repaired tetralogy of Fallot?
4D flow cardiac magnetic resonance is a valuable imaging modality for identifying paravalvular leak as the underlying cause of bioprosthetic pulmonary valve dysfunction.
Answers are grounded in this paper and cite their sources.
4D-flow CMR detects paravalvular leak in bioprosthetic pulmonary valve failure; leaves open its diagnostic role pending larger validation studies.
We present a case of a 20-year-old man with tetralogy of Fallot status post-repair with a transannular patch and left pulmonary artery reconstruction at age 1 and subsequent pulmonary valve replacement with bioprosthetic valve 3 years ago. A transthoracic echocardiogram revealed severe bioprosthetic valve insufficiency. Cardiac magnetic resonance with 4-dimensional flow revealed a paravalvular leak. (Level of Difficulty: Intermediate.)
No takes yet. Share an insight, caveat, or question.
Rotman et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: