Why the study?
Does LBM-based computational hemodynamics using MRI accurately measure pressure gradients compared to invasive catheterization in patients with aortic coarctation?
Does LBM-based computational hemodynamics using MRI accurately measure pressure gradients compared to invasive catheterization in patients with aortic coarctation?
LBM-based computational hemodynamics using MRI provides noninvasive pressure gradient measurements that correlate well with invasive catheterization in patients with aortic coarctation.
Answers are grounded in this paper and cite their sources.
May offer noninvasive CoA pressure gradients; leaves open larger validation before clinical use.
PURPOSE: To introduce a scheme based on a recent technique in computational hemodynamics, known as the lattice Boltzmann methods (LBM), to noninvasively measure pressure gradients in patients with a coarctation of the aorta (CoA). To provide evidence on the accuracy of the proposed scheme, the computed pressure drop values are compared against those obtained using the reference standard method of catheterization. MATERIALS AND METHODS: Pre- and posttreatment LBM-based pressure gradients for 12 patients with CoA were simulated for the time point of peak systole using the open source library OpenLB. Four-dimensional (4D) flow-sensitive phase-contrast MRI at 1.5 Tesla was used to acquire flow and to setup the simulation. The vascular geometry was reconstructed using 3D whole-heart MRI. Patients underwent pre- and postinterventional pressure catheterization as a reference standard. RESULTS: There is a significant linear correlation between the pretreatment catheter pressure drops and those computed based on the LBM simulation, r=.85, P<.001. The bias was -0.58 ± 4.1 mmHg and was not significant ( P=0.64) with a 95% confidence interval (CI) of -3.22 to 2.06. For the posttreatment results, the bias was larger and at -2.54 ± 3.53 mmHg with a 95% CI of -0.17 to -4.91 mmHg. CONCLUSION: The results indicate a reasonable agreement between the simulation results and the catheter measurements. LBM-based computational hemodynamics can be considered as an alternative to more traditional computational fluid dynamics schemes for noninvasive pressure calculations and can assist in diagnosis and therapy planning. LEVEL OF EVIDENCE: 3 J. Magn. Reson. Imaging 2017;45:139-146.
No takes yet. Share an insight, caveat, or question.
Mirzaee et al. (2016) studied this question.