Why the study?
Patients with aortic valve disease can develop valve insufficiency after repair due to aortic root dilatation, prompting investigation into optimal valve height to ensure complete closure and smooth flow.
Does valve height affect the opening and closing performance of the aortic valve under aortic root dilatation in 3D finite element models?
Does valve height affect the opening and closing performance of the aortic valve under aortic root dilatation in 3D finite element models?
Answers are grounded in this paper and cite their sources.
A valve height of 14.5 mm optimally adapts to aortic root dilatation by minimizing stress and maintaining adequate geometric orifice area, suggesting its importance in surgical planning for aortic valve repair.
Patients with aortic valve disease can suffer from valve insufficiency after valve repair surgery due to aortic root dilatation. The paper investigates the effect of valve height (Hv) on the aortic valve opening and closing in order to select the appropriate range of Hv for smoother blood flow through the aortic valve and valve closure completely in the case of continuous aortic root dilatation. A total of 20 parameterized three-dimensional models of the aortic root were constructed following clinical surgical guidance. Aortic annulus diameter (DAA) was separately set to 26, 27, 28, 29, and 30 mm to simulate aortic root dilatation. H V value was separately set to 13.5, 14, 14.5, and 15 mm to simulate aortic valve alterations in surgery. Time-varying pressure loads were applied to the valve, vessel wall of the ascending aorta, and left ventricle. Then, finite element analysis software was employed to simulate the movement and mechanics of the aortic root. The feasible design range of the valve size was evaluated using maximum stress, geometric orifice area (GOA), and leaflet contact force. The results show that the valve was incompletely closed when H V was 13.5 mm and D AA was 29 or 30 mm. The GOA of the valve was small when H V was 15 mm and D AA was 26 or 27 mm. The corresponding values of the other models were within the normal range. Compared with the model with an H V of 14 mm, the model with an H V of 14.5 mm could effectively reduce maximum stress and had relatively larger GOA and less change in contact force. As a result, valve height affects the performance of aortic valve opening and closing. Smaller H V is adapted to smaller D AA and vice versa. When H V is 14.5 mm, the valve is well adapted to the dilatation of the aortic root to enhance repair durability. Therefore, more attention should be paid to H V in surgical planning.
No takes yet. Share an insight, caveat, or question.
Hou et al. (2021) studied this question.