Why the study?
Does one-point carotid pulse wave velocity correlate with carotid-femoral pulse wave velocity in a mixed population of healthy subjects and patients with cardiovascular conditions?
Does one-point carotid pulse wave velocity correlate with carotid-femoral pulse wave velocity in a mixed population of healthy subjects and patients with cardiovascular conditions?
One-point carotid pulse wave velocity measured by echo-tracking correlates significantly with standard carotid-femoral pulse wave velocity and can identify patients with elevated arterial stiffness.
Answers are grounded in this paper and cite their sources.
Supports one-point carotid PWV as a potential surrogate; leaves open prospective validation before clinical adoption.
OBJECTIVES: Recently, echo-tracking-derived measures of arterial stiffness have been introduced in clinical practice for the assessment of one-point pulse wave velocity. The purpose of this study was to find a relation between carotid-femoral pulse wave velocity and one-point carotid pulse wave velocity, and to find a value of one-point carotid pulse wave velocity that predicts carotid-femoral pulse wave velocity higher than 12 m/s. METHODS: A total of 160 consecutive subjects (112 male/48 female, mean age = 51.5 ± 14.1 years; 96 healthy, 44 hypertensives, 13 with aortic valve disease, and 7 with left ventricular dysfunction) were studied. Carotid-femoral pulse wave velocity was measured with the SphygmoCor system and one-point carotid pulse wave velocity with high-definition echo-tracking system (ProSound Alpha10; Aloka, Tokyo, Japan). RESULTS: Both carotid-femoral pulse wave velocity and one-point carotid pulse wave velocity correlated significantly with each other (r = 0.539, p < 0.001) and with age (one-point carotid pulse wave velocity r = 0.618, carotid-femoral pulse wave velocity r = 0.617, p < 0.0001 for both). Median value of carotid-femoral pulse wave velocity (7.2 m/s, 95% confidence interval = 6.2-8.9) was systematically higher than that of one-point carotid pulse wave velocity (5.8 m/s, 95% confidence interval = 5-6.6). The area under the receiver operating characteristic curve was 0.85, identifying the cutoff for one-point pulse wave velocity of 6.65 m/s as the best predictor of carotid-femoral pulse wave velocity more than 12 m/s (sensitivity = 0.818, specificity = 0.819). CONCLUSIONS: One-point carotid pulse wave velocity correlates with carotid-femoral pulse wave velocity, and the cutoff of 6.65 m/s was the best predictor of carotid-femoral pulse wave velocity over 12 m/s.
No takes yet. Share an insight, caveat, or question.
Vriz et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: