Answers are grounded in this paper and cite their sources.
Laboratory study demonstrates detection of aqueous paraoxon using immobilized organophosphorus hydrolase on quartz, suggesting viable biosensor designs for dangerous organophosphorus toxins.
As a consequence of organophosphorus (OP) toxins posing a threat to human life globally, organophosphorus hydrolase (OPH) has become the enzyme of choice to detoxify such compounds. Organophosphorus hydrolase was covalently immobilized onto a quartz substrate for utilization in paraoxon detection. The substrate was cleaned and modified prior to chemical attachment. Each modification step was monitored by imaging ellipsometry as the thickness increased with each modification step. The chemically attached OPH was labeled with a fluorescent dye (7-isothiocyanato-4-methylcoumarin) for the detection of paraoxon in aqueous solution, ranging from 10(-9) to 10(-5) M. UV-visible spectra were also acquired for the determination of the hydrolysis product of para-oxon, namely p-nitrophenol.
No takes yet. Share an insight, caveat, or question.
Orbulescu et al. (2006) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: