The reduction of carrier generation lifetime caused by argon implantation into silicon has been studied as a function of argon dose and annealing treatments. The capacitance transient technique was used to deduce that: ( i ) carrier generation lifetime in the depletion region decreases by four orders of magnitude with doses up to 10 14 cm −2 , and varies inversely with dose; ( ii ) the separable contribution to capacitance relaxation due to surface generation and diffusion varies as the square of the dose. The region of low lifetime appears to remain localized within 1 μm from the surface even after annealing for 1h at 1200°C. Partial recovery of generation lifetime occurs after annealing for 1h at 1100° or 1200°C. Complete recovery was observed only after several hours at 1200°C, and slow cooling (2°C min −1 ). The resistance to high temperature treatment implies that regions of low lifetime can be incorporated with three‐dimensional control into device structures.
No takes yet. Share an insight, caveat, or question.
Mogro‐Campero et al. (1984) studied this question.