Why the study?
The newly formed geometry between the native Valsalva and implanted transcatheter heart valve may induce local thrombogenicity, but the incidence and clinical outcomes of Valsalva thrombus formation after TAVI required assessment.
Does Valsalva thrombus formation after balloon-expandable TAVI increase the risk of adverse clinical outcomes?
Does Valsalva thrombus formation after balloon-expandable TAVI increase the risk of adverse clinical outcomes?
Valsalva thrombus occurs in nearly 9% of patients after balloon-expandable TAVI but does not appear to increase the risk of death, stroke, or heart failure readmission at two years.
Valsalva thrombus after TAVI may warrant closer MDCT surveillance; leaves open need for prospective studies on antithrombotic management.
AIMS: The newly formed geometry between the native Valsalva and implanted transcatheter heart valve (THV) may induce local thrombogenicity. This study aimed to assess the incidence of and the clinical outcomes associated with Valsalva thrombus formation after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: We retrospectively evaluated the multidetector computed tomography (MDCT) data of 338 patients following transcatheter aortic valve implantation (TAVI) using a balloon-expandable THV. The Valsalva and leaflet thrombi were assessed by MDCT at the left coronary cusp (LCC), right coronary cusp (RCC), and non-coronary cusp (NCC). Combined endpoints such as death, stroke, and readmission for heart failure rates in patients with and without Valsalva and/or leaflet thrombus were examined at two years. The overall incidence of Valsalva and leaflet thrombi was 8.9% and 8.3%, respectively. Significant differences in the location of the Valsalva thrombus in the LCC, RCC, and NCC were noted (5.0%, 4.2%, 8.9%, respectively, p<0.001). The independent predictor for increased risk of Valsalva thrombus was high Valsalva area to implanted THV size ratio (odds ratio 11.8, 95% confidence interval [CI]: 1.67-83.0, p=0.013). Combined endpoints were similar in patients with and without Valsalva thrombus, Valsalva/leaflet thrombus, and leaflet thrombus (p>0.05 for all). CONCLUSIONS: Valsalva thrombus was detected in 8.9% of patients following balloon-expandable THV implantation and was common in the LCC, but it did not increase the risk of adverse events after TAVI.
No takes yet. Share an insight, caveat, or question.
Tsunaki et al. (2019) studied this question.