Why the study?
Does increasing the number of semi-automatic blood pressure readings improve blood pressure reproducibility in mild essential hypertensive patients?
Does increasing the number of semi-automatic blood pressure readings improve blood pressure reproducibility in mild essential hypertensive patients?
Multiple semi-automatic blood pressure readings in the clinic progressively increase blood pressure reproducibility, achieving levels comparable to 24-hour ambulatory monitoring.
Answers are grounded in this paper and cite their sources.
Multiple semi-automatic clinic readings may match ABPM reproducibility in mild hypertension; leaves open whether this improves outcomes or warrants practice change.
Objective To evaluate whether increasing the number of blood pressure readings obtained in the clinic environment increases the blood pressure reproducibility Patients: Thirteen mild essential hypertensive patients studied in the outpatient clinics, following withdrawal of antihypertensive treatment for 4 weeks Methods The systolic and diastolic blood pressures were measured three times, using a mercury sphygmomanometer, with the patient in the sitting position. Measurements were then performed with the patient in the lying position using an oscillometric device (SpaceLabs 90202 or 90207). The device was operated semi-automatically at 3-min intervals until 25 readings had been collected. The same procedure was repeated 4 weeks later. The systolic blood pressure, diastolic blood pressure and heart rate were averaged by considering a progressively greater number of readings, from 1 to 25. The reciprocal of the standard deviation (1/SD) of the mean difference after 4 weeks was taken as the measure of reproducibility Results 1/SD increased progressively as the number of semi-automatic blood pressure readings from which the average was calculated increased. For a similar number of blood pressure readings the reproducibility was similar for semi-automatic readings to that for automatic readings obtained by 24-h ambulatory blood pressure monitoring Conclusion Multiple blood pressure readings obtained semi-automatically in the outpatient clinics increase blood pressure reproducibility and make the value similar to that obtained by ambulatory blood pressure monitoring. The advantage of an increase in reproducibility for studies on antihypertensive drugs thus depends on the number of readings, and can also be obtained by semi-automatic measurements in the clinic environment
No takes yet. Share an insight, caveat, or question.
Mancia et al. (1994) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: