Key result
AV ablation and permanent ventricular pacemaker implantation were successfully performed without fluoroscopy using the EnSite NavX electroanatomic navigation system in a 47-year-old man.
Why the study?
Can AV node ablation and permanent ventricular pacemaker implantation be successfully performed without fluoroscopy using an electroanatomic navigation system in a patient with uncontrollable permanent atrial fibrillation?
Case Report (n=1)
Can AV node ablation and permanent ventricular pacemaker implantation be successfully performed without fluoroscopy using an electroanatomic navigation system in a patient with uncontrollable permanent atrial fibrillation?
This case demonstrates the feasibility of performing AV node ablation and permanent ventricular pacemaker implantation entirely without fluoroscopy using an electroanatomic navigation system, potentially reducing radiation exposure.
Answers are grounded in this paper and cite their sources.
Supports feasibility of zero-fluoroscopy AV ablation with pacemaker; leaves open safety and efficacy in larger populations.
Non-fluoroscopy AV ablation and pacemaker implantation. Fluoroscopic guidance is the standard tool used for transvenous pacemaker implantations and for electrophysiological and ablation procedures. It implies X-ray exposure, occasionally with high dose of radiation for the patient and operator. We describe the case of a 47-year-old man with uncontrollable permanent atrial fibrillation to whom ablation of the AV conduction and a permanent ventricular pacemaker implantation were successfully performed under the guidance of an electroanatomic navigation EnSite NavX system and with no use of fluoroscopy. This case illustrates the stand-alone use of one of the new non-fluoroscopic navigation systems for a complete procedure such as AV ablation and pacemaker implantation.
No takes yet. Share an insight, caveat, or question.
Ruiz‐Granell et al. (2005) conducted a case report in Uncontrollable permanent atrial fibrillation (n=1). AV ablation and permanent ventricular pacemaker implantation using EnSite NavX system without fluoroscopy was evaluated on Successful ablation of AV conduction and permanent ventricular pacemaker implantation with no use of fluoroscopy. AV ablation and permanent ventricular pacemaker implantation were successfully performed without fluoroscopy using the EnSite NavX electroanatomic navigation system in a 47-year-old man.