Key result
A HAVOC score ≥5 was associated with a higher rate of new incident atrial fibrillation compared to a score of 0-4 after embolic stroke.
Why the study?
The HAVOC score was proposed to predict atrial fibrillation after cryptogenic stroke, but its performance needed external assessment in patients with embolic stroke of undetermined source.
Does the HAVOC score accurately predict new incident atrial fibrillation in patients with embolic stroke of undetermined source?
Cohort (n=658)
Does the HAVOC score accurately predict new incident atrial fibrillation in patients with embolic stroke of undetermined source?
Answers are grounded in this paper and cite their sources.
The HAVOC score demonstrated only modest accuracy (AUC 68.7%) in predicting incident AF in an external cohort of ESUS patients, failing to confirm the low risk previously reported for scores 0-4.
Background and Purpose- The HAVOC score (hypertension, age, valvular heart disease, peripheral vascular disease, obesity, congestive heart failure, coronary artery disease) was proposed for the prediction of atrial fibrillation (AF) after cryptogenic stroke. It showed good model discrimination (area under the curve, 0.77). Only 2.5% of patients with a low-risk HAVOC score (ie, 0-4) were diagnosed with new incident AF. We aimed to assess its performance in an external cohort of patients with embolic stroke of undetermined source. Methods- In the AF-embolic stroke of undetermined source dataset, we assessed the discriminatory power, calibration, specificity, negative predictive value, and accuracy of the HAVOC score to predict new incident AF. Patients with a HAVOC score of 0 to 4 were considered as low-risk, as proposed in its original publication. Results- In 658 embolic stroke of undetermined source patients (median age, 67 years; 44% women), the median HAVOC score was 2 (interquartile range, 3). There were 540 (82%) patients with a HAVOC score of 0 to 4 and 118 (18%) with a score of ≥5. New incident AF was diagnosed in 95 (14.4%) patients (28.8% among patients with HAVOC score ≥5 and 11.3% among patients with HAVOC score 0-4 [age- and sex-adjusted odds ratio, 2.29 (95% CI, 1.37-3.82)]). The specificity of low-risk HAVOC score to identify patients without new incident AF was 88.7%. The negative predictive value of low-risk HAVOC score was 85.1%. The accuracy was 78.0%, and the area under the curve was 68.7% (95% CI, 62.1%-73.3%). Conclusions- The previously reported low rate of AF among embolic stroke of undetermined source patients with low-risk HAVOC score was not confirmed in our cohort. Further assessment of the HAVOC score is warranted before it is routinely implemented in clinical practice.
No takes yet. Share an insight, caveat, or question.
Ntaios et al. (2019) conducted a cohort in Embolic stroke of undetermined source (n=658). HAVOC score ≥5 vs. HAVOC score 0-4 was evaluated on New incident atrial fibrillation (OR 2.29, 95% CI 1.37-3.82). A HAVOC score ≥5 was associated with a higher rate of new incident atrial fibrillation compared to a score of 0-4 after embolic stroke.
Synapse has enriched 10 related papers. Consider them for comparative context: