Answers are grounded in this paper and cite their sources.
The adhesion of pyromellitic dianhydride-oxydianiline polyimide (PMDA-ODA) to clean and fluorine-contaminated silicon oxide (SiO2 and F-SiO2, respectively) surfaces was studied by the peel test. A 50% drop in the peel force was observed for PMDA-ODA on F-SiO2 as compared to that on SiO2 measured at low (11-22%) ambient humidity. It was also found that the PMDA-ODA adhesion strength to F-SiO2 was a strong function of the humidity. A 21/2-fold increase in the humidity caused over an order of magnitude decrease in the peel force of PMDA-ODA on F-SiO2, which was only about 5% of the peel force measured under the same ambient conditions for PMDA-ODA on the SiO2 surface. A careful analysis further demonstrated that the basic mechanical properties of the polyimide film were unaffected to within experimental error. The most probable cause of the adhesion loss is thus attributed to moisture attack in the polyimide-substrate interface region. The locus of failure in the case of PMDA-ODA on SiO2 is in an apparent weak boundary layer of the polyimide, while for polyimide on F-SiO2 the failure locus is mixed within the polyimide and the F-SiO2. An estimate of the work of adhesion (interface fracture energy) was made using the high (40-55%) humidity peel data for PMDA-ODA on the F-SiO2 surface, giving a value of 6 J/m2.
No takes yet. Share an insight, caveat, or question.
Buchwalter et al. (1988) studied this question.