Key result
Baseline brachial-ankle pulse wave velocity ≥ 1,400 cm/s was independently associated with a 52% increased risk of new carotid plaque formation compared to < 1,400 cm/s.
Why the study?
Does elevated baseline brachial-ankle pulse wave velocity (≥1,400 cm/s) predict new carotid plaque formation in a community-based population without baseline plaques?
Cohort (n=738)
No
Does elevated baseline brachial-ankle pulse wave velocity (≥1,400 cm/s) predict new carotid plaque formation in a community-based population without baseline plaques?
Elevated baseline brachial-ankle pulse wave velocity (≥1,400 cm/s) is an independent predictor of new carotid plaque formation, suggesting its utility as an early marker for atherosclerosis risk.
Answers are grounded in this paper and cite their sources.
Supports baPWV in observational risk assessment; leaves open whether stiffness reduction prevents plaque.
Artery stiffness is an independent marker for atherosclerotic cardiovascular diseases. However, whether the brachial-ankle pulse wave velocity (ba-PWV) is related to new carotid plaque formation is unresolved. This study aimed to investigate the association between baseline ba-PWV and new carotid plaque formation in a Chinese community-based population without carotid plaques at baseline. This study population consisted of a total of 738 participants from an atherosclerosis cohort in Beijing, China. After a mean 2.3-year follow-up, the incidence of carotid plaques were 21.2% and 36.5% in the groups with ba-PWV < 1,400 cm/s and ≥1,400 cm/s, respectively. Compared with baseline ba-PWV < 1,400 cm/s group, ba-PWV ≥ 1,400 cm/s group was significantly associated with the incidence of new carotid plaque formation (odds ratio [OR] = 2.14, 95% CI: 1.50-3.03, P < 0.01), even after adjusting for common risk factors (OR = 1.52, 95% CI: 1.02-2.25, P = 0.04). Furthermore, there was a strong relationship between baseline ba-PWV and carotid plaque formation in subjects with ba-PWV < 1,400 cm/s, but no such relationship was found in subjects with baseline ba-PWV ≥ 1,400 cm/s. In conclusion, this study suggests that baseline ba-PWV is independently associated with the risk of carotid plaque formation in a Chinese community-based population.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2018) conducted a cohort in Carotid plaque formation (n=738). Baseline ba-PWV ≥ 1,400 cm/s vs. Baseline ba-PWV < 1,400 cm/s was evaluated on Incidence of new carotid plaque formation (OR 1.52, 95% CI 1.02-2.25, p=0.04). Baseline brachial-ankle pulse wave velocity ≥ 1,400 cm/s was independently associated with a 52% increased risk of new carotid plaque formation compared to < 1,400 cm/s.
Synapse has enriched 10 related papers. Consider them for comparative context: