Key result
Rosette cMRF achieves simultaneous water-fat separation and yields ~2-ms higher myocardial T2 values than spiral cMRF.
Why the study?
The authors aimed to develop an approach for simultaneous water-fat separation and myocardial T1 and T2 quantification using cardiac MR fingerprinting with rosette trajectories at 3T and 1.5T.
Does cardiac MR fingerprinting with rosette trajectories achieve accurate simultaneous myocardial T1 and T2 quantification and water-fat separation compared with spiral cMRF and conventional mapping sequences in healthy subjects at 3T and 1.5T?
Does cardiac MR fingerprinting with rosette trajectories achieve accurate simultaneous myocardial T1 and T2 quantification and water-fat separation compared with spiral cMRF and conventional mapping sequences in healthy subjects at 3T and 1.5T?
Rosette cardiac MR fingerprinting enables simultaneous myocardial T1 and T2 mapping, B0 inhomogeneity correction, and water-fat separation within a single 15-heartbeat breath-hold scan at both 1.5T and 3T.
Answers are grounded in this paper and cite their sources.
Rosette cMRF supports efficient multiparametric mapping development; leaves open validation in patients and against reference standards.
Purpose This work aims to develop an approach for simultaneous water–fat separation and myocardial T 1 and T 2 quantification based on the cardiac MR fingerprinting (cMRF) framework with rosette trajectories at 3T and 1.5T. Methods Two 15‐heartbeat cMRF sequences with different rosette trajectories designed for water–fat separation at 3T and 1.5T were implemented. Water T 1 and T 2 maps, water image, and fat image were generated with B 0 inhomogeneity correction using a B 0 map derived from the cMRF data themselves. The proposed water–fat separation rosette cMRF approach was validated in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and water/oil phantoms. It was also applied for myocardial tissue mapping of healthy subjects at both 3T and 1.5T. Results Water T 1 and T 2 values measured using rosette cMRF in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom agreed well with the reference values. In the water/oil phantom, oil was well suppressed in the water images and vice versa. Rosette cMRF yielded comparable T 1 but 2~3 ms higher T 2 values in the myocardium of healthy subjects than the original spiral cMRF method. Epicardial fat deposition was also clearly shown in the fat images. Conclusion Rosette cMRF provides fat images along with myocardial T 1 and T 2 maps with significant fat suppression. This technique may improve visualization of the anatomical structure of the heart by separating water and fat and could provide value in diagnosing cardiac diseases associated with fibrofatty infiltration or epicardial fat accumulation. It also paves the way toward comprehensive myocardial tissue characterization in a single scan.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2020) studied Healthy subjects (plus ISMRM/NIST and water/oil phantoms) (n=16). Cardiac MR fingerprinting (cMRF) with rosette trajectories and B0 inhomogeneity correction vs. Original 15-heartbeat spiral cMRF with fat saturation and conventional T1/T2 mapping (MOLLI, T2-prepared FLASH, T2-prepared bSSFP) was evaluated on Myocardial T2 relaxation time (ms) at 3T comparing rosette cMRF versus spiral cMRF (p=<0.01). Rosette cMRF achieved simultaneous water-fat separation and myocardial mapping, yielding comparable T1 and higher T2 values at 3T than spiral cMRF.