Why the study?
Does placing the edge of tangent fields at least 2.5 mm from the LAD maintain LADmax <10 Gy in women receiving prone accelerated left breast radiation therapy?
Does placing the edge of tangent fields at least 2.5 mm from the LAD maintain LADmax <10 Gy in women receiving prone accelerated left breast radiation therapy?
Answers are grounded in this paper and cite their sources.
Placing the edge of tangent fields at least 2.5 mm from the LAD during prone accelerated left breast radiation therapy reliably maintains LADmax <10 Gy, which may help reduce the risk of cardiovascular toxicity.
PURPOSE: Maximum dose to the left anterior descending artery (LADmax) is an important physical constraint to reduce the risk of cardiovascular toxicity. We generated a simple algorithm to guide the positioning of the tangent fields to reliably maintain LADmax <10 Gy. METHODS AND MATERIALS: Dosimetric plans from 146 consecutive women treated prone to the left breast enrolled in prospective protocols of accelerated whole breast radiation therapy, with a concomitant daily boost to the tumor bed (40.5 Gy/15 fraction to the whole breast and 48 Gy to the tumor bed), provided the training set for algorithm development. Scatter plots and correlation coefficients were used to describe the bivariate relationships between LADmax and several parameters: distance from the tumor cavity to the tangent field edge, cavity size, breast separation, field size, and distance from the tangent field. A logistic sigmoid curve was used to model the relationship of LADmax and the distance from the tangent field. Furthermore, we tested this prediction model on a validation data set of 53 consecutive similar patients. RESULTS: A lack of linear relationships between LADmax and distance from cavity to LAD (-0.47), cavity size (-0.18), breast separation (-0.02), or field size (-0.28) was observed. In contrast, distance from the tangent field was highly negatively correlated to LADmax (-0.84) and was used in the models to predict LADmax. From a logistic sigmoid model we selected a cut-point of 2.46 mm (95% confidence interval, 2.19-2.74 mm) greater than which LADmax is <10 Gy (95% confidence interval, 9.30-10.72 Gy) and LADmean is <3.3 Gy. CONCLUSIONS: Placing the edge of the tangents at least 2.5 mm from the closest point of the contoured LAD is likely to assure LADmax is <10 Gy and LADmean is <3.3 Gy in patients treated with prone accelerated breast radiation therapy.
No takes yet. Share an insight, caveat, or question.
Cooper et al. (2016) studied this question.