Why the study?
Do point-of-care troponin assays provide comparable diagnostic performance to central laboratory high-sensitivity troponin assays for predicting myocardial infarction in emergency department patients?
Do point-of-care troponin assays provide comparable diagnostic performance to central laboratory high-sensitivity troponin assays for predicting myocardial infarction in emergency department patients?
Point-of-care troponin assays demonstrate equivalent diagnostic performance to central laboratory high-sensitivity assays for suspected MI, but require eGFR-specific cut-offs in patients with impaired renal function to decrease false-positives.
Answers are grounded in this paper and cite their sources.
POC cTn assays match hs-TnT performance for MI diagnosis in ED patients; supports POC use while leaving optimal eGFR-adjusted cut-offs open.
Early diagnosis of myocardial infarction (MI) with cardiac troponin (cTn) assays at the point-of-care (POC) is suggested to shorten turn-around-time in the emergency department (ED). The present study aimed at comparing the diagnostic performance of two POC cTn assays with that of a central laboratory high-sensitivity (hs) method, under routine ED conditions. In 2,163 non-selected ED patients suspected for MI, the diagnostic performance of the POC troponin I (TnI), troponin T (TnT), and hs-TnT assay for the prediction of MI was evaluated based on receiver operating characteristic (ROC) analyses and compared with the performance based on the manufacturers' cut-offs. Due to an observed association between renal function as determined by estimated glomerular filtration rate (eGFR) and cTn concentrations, all analyses were stratified by renal function. In patients with normal renal function (eGFR > 60 mL/min/1.73m2), POC and hs assays showed a comparable diagnostic performance as quantified by the area under the ROC curve (AUC) of about 0.88. The ROC-derived optimal cut-off (OCO) levels for the different cTn assays clearly changed with decreasing kidney function. Impaired kidney function required OCO to be three to five times higher to achieve a comparable performance. Particularly cTnT concentrations were strongly associated with renal function. The three cTn assays demonstrated equivalent diagnostic performance in ED-patients admitted with suspected ACS in relation to the release diagnosis, supporting the use of POC testing in this setting. The present results implicate that application of eGFR-specific OCOs may decrease false-positives among patients with impaired renal function. Providing individual cut-offs depending on patients' eGFR might be an appropriate add-on tool to improve specificity in the diagnosis of MI.
No takes yet. Share an insight, caveat, or question.
Wilke et al. (2017) studied this question.