Does therapeutic optimization using echo-Doppler data improve accuracy in defining hemodynamic profiles and influence therapeutic management compared to right heart catheterization in patients with chronic heart failure?
Does therapeutic optimization using echo-Doppler data improve accuracy in defining hemodynamic profiles and influence therapeutic management compared to right heart catheterization in patients with chronic heart failure?
Echo-Doppler hemodynamic monitoring is highly accurate in estimating hemodynamic profiles in chronic heart failure patients and influences therapeutic management similarly to right heart catheterization.
Echo-Doppler improves hemodynamic profiling accuracy over clinical assessment in chronic HF; supports its role guiding therapy as noninvasive alternative to catheterization.
BACKGROUND: Correct classification of chronic heart failure (CHF) patients by dual evidence of congestion and adequate perfusion is the primary clinical focus for management. OBJECTIVES: To evaluate the accuracy of echo-Doppler compared with clinical evaluation in determining the hemodynamic profile of patients with CHF; and to compare therapeutic changes based on hemodynamic or echo-Doppler findings. METHODS: Three hundred and sixty-six consecutive CHF patients (ejection fraction 25+/-7%) in sinus rhythm, undergoing evaluation for cardiac transplantation, underwent physical examination prior to right heart catheterization and echo-Doppler studies. Subsequently, patients were randomized to therapeutic optimization using either right heart catheterization or echo-Doppler data. The end-points were: identification of low cardiac output (cardiac index <2.2 l/min/m(2)); high pulmonary wedge pressure (PWP >18 mm Hg); high right atrial pressure (RAP >5 mm Hg) and analysis of therapeutic changes made in response to the right heart catheterization and echo-Doppler studies. RESULTS: Echo-Doppler showed better accuracy in estimating abnormal hemodynamic indices than clinical variables (cardiac index <2.2 l/min/m(2): echo positive predictive accuracy (PPA) 98% vs. clinical PPA 52% p<0.00001; PWP >18 mm Hg: echo PPA 85% vs. clinical PPA 76% p=0.0011; RAP >5 mm Hg: echo PPA 82% vs. clinical PPA 57% p<0.00001). When applied to individual patients, the echo-Doppler assessment was more accurate than clinical evaluation in defining the different hemodynamic profiles: wet/cold (89% vs. 13%, p<0.0001); wet/warm (73% vs. 30%, p<0.0001); dry/cold (68% vs. 12%, p<0.0001); dry/warm (88% vs. 51%, p<0.0001). Therapeutic decision-making based on echo-Doppler findings was similar to that based on hemodynamics. CONCLUSION: Echo-Doppler hemodynamic monitoring proved accurate in estimating hemodynamic profiles and influenced therapeutic management.
No takes yet. Share an insight, caveat, or question.
Capomolla et al. (2004) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: