Key result
Tetralogy of Fallot repair depresses LV function, with LV area diverging by preoperative shunt direction.
Why the study?
Does the direction of preoperative ventricular septal defect shunting (right-to-left vs. left-to-right) affect acute changes in left ventricular mechanics and function after surgical repair of Tetralogy of Fallot?
Cohort (n=11)
No
Does the direction of preoperative ventricular septal defect shunting (right-to-left vs. left-to-right) affect acute changes in left ventricular mechanics and function after surgical repair of Tetralogy of Fallot?
Surgical repair of Tetralogy of Fallot acutely depresses both systolic and diastolic left ventricular function, with preoperative shunt direction dictating opposite changes in postoperative LV preload (increased EDA in "blue" R-L TOF vs. decreased EDA in "pink" L-R TOF), suggesting tailored postoperative management with inotropes for R-L TOF and volume loading for L-R TOF.
Answers are grounded in this paper and cite their sources.
Shunt direction associated with divergent post-repair LV preload; leaves open whether tailored management improves TOF outcomes.
BACKGROUND: Tetralogy of Fallot (TOF) typically results in clinical cyanosis or volume overload of the left ventricle (LV), depending on the direction and magnitude of shunting across the ventricular septal defect (VSD). The present study examines the effects of surgical TOF repair on LV mechanics and compares these changes between patients with VSD shunts that are predominantly right-to-left (R-L; "blue TOF") and those with VSD shunts that are predominantly left-to-right (L-R; "pink TOF"). METHODS AND RESULTS: Eleven patients (6 R-L and 5 L-R) 4.3 to 18.4 months old (median 7.1 months old) were studied. LV end-diastolic area (EDA) was calculated from transesophageal echocardiograms obtained during initiation and weaning of cardiopulmonary bypass. LV end-diastolic pressure was measured by micromanometer. Compliance was assessed by end-diastolic pressure-area curves. Contractility was assessed from preload recruitable stroke work by the stroke work-versus-LV EDA relation. VSD shunt direction was determined by preoperative Doppler echocardiography. Changes in LV function at the conclusion of cardiopulmonary bypass included decreased stroke area (from 6.6 +/- 0.9 to 4.1 +/- 0.4 cm(2)/m(2), P=0.012) and ejection fraction (from 55 +/- 2% to 41 +/- 3%, P<0.001). LV EDA at a common pressure in 8 patients decreased (from 10.4 +/- 1.4 to 7.6 +/- 1.2 cm(2)/m(2), P=0.003), which suggests a decrease in ventricular compliance. Additionally, the end-diastolic pressure-area curves shifted to the left in all patients. Preload recruitable stroke work decreased (from 34.8 +/- 2.4 to 21.8 +/- 2.6 mm Hg, P=0.007), which demonstrates a decrease in ventricular contractility. When separated by preoperative shunt direction, LV EDA increased in R-L patients by 0.9+/-0.5 cm(2)/m(2) postoperatively but decreased in L-R patients by 4.3 +/- 0.8 cm(2)/m(2) (P<0.001). Area ejection fraction decreased in all patients independent of shunting or change in LV EDA. CONCLUSIONS: LV diastolic and systolic function are depressed after TOF repair. Mechanical effects of the VSD patch and myocardial depressant effects of ischemia and reperfusion during surgery probably contribute to the observed changes in LV mechanics. Different effects of surgical repair on LV preload in pink and blue TOF also contribute to the spectrum of clinical results observed after surgery.
No takes yet. Share an insight, caveat, or question.
Richmond et al. (2008) conducted a cohort in Tetralogy of Fallot undergoing complete surgical repair (n=11). Predominant right-to-left preoperative ventricular septal defect shunting (blue TOF) undergoing surgical repair vs. Predominant left-to-right preoperative ventricular septal defect shunting (pink TOF) undergoing surgical repair was evaluated on Postoperative change in left ventricular end-diastolic area (LV EDA, cm2/m2) by preoperative shunt direction (p=<0.001). Surgical Tetralogy of Fallot repair depressed left ventricular function overall, while LV end-diastolic area increased by 0.9 cm2/m2 in right-to-left shunts vs decreased by 4.3 cm2/m2 in left-to-right shunts (P<0.001).
Synapse has enriched 10 related papers. Consider them for comparative context: