Key result
A left-sided Cryomaze procedure during mitral valve surgery achieved 87% freedom from atrial fibrillation at a mean follow-up of 305 days.
Why the study?
Does a left-sided Cryomaze procedure restore sinus rhythm in patients with atrial fibrillation undergoing mitral valve surgery?
Cohort (n=141)
Does a left-sided Cryomaze procedure restore sinus rhythm in patients with atrial fibrillation undergoing mitral valve surgery?
A left-sided Cryomaze procedure performed during mitral valve surgery effectively restores sinus rhythm, with success rates increasing over the first year but dependent on preoperative factors like left atrial size.
Answers are grounded in this paper and cite their sources.
Supports adjunctive left-sided Cryomaze in mitral valve surgery with AF; hypothesis-generating and requires randomized confirmation.
Surgical treatment of atrial fibrillation (AF) using a variety of energy sources and a mixture of lesion sets has become an important adjunct in patients undergoing cardiac surgery. We retrospectively analyzed prospectively collected data of 141 patients with a history of AF (mean duration of AF 35+/-39 months; intermittent AF: n=72; 51%; permanent AF: 69 (49%)) who underwent a left-sided Cryomaze procedure in conjunction with mitral valve (MV) surgery between January 2003 and September 2006. Freedom from AF was 77% at discharge and 87% at a mean follow-up of 305+/-195 days with a decreasing rate of AF during the first 3-9 months from 13% to 9% and an increase beyond the first year (29% at 2 years). Predictors of failed Cryomaze in multivariate analysis were left atrial size >50 mm (OR=5.7), AF at surgery (OR=5.0) and cardiac reoperation (OR=3.4), whereas preoperative beta-blocker treatment was a predictor of success (OR=0.2). Our data suggest that a left-sided Cryomaze procedure effectively restores sinus rhythm in patients with AF undergoing MV surgery. The success rate should not be evaluated immediately postoperatively because there is a steady increase in the rate of patients with freedom from AF in the first year. It appears, however, that there is a higher rate of recurrence during later follow-up.
No takes yet. Share an insight, caveat, or question.
Rahmanian et al. (2008) conducted a cohort in Atrial fibrillation (n=141). Left-sided Cryomaze procedure was evaluated on Freedom from atrial fibrillation at mean follow-up. A left-sided Cryomaze procedure during mitral valve surgery achieved 87% freedom from atrial fibrillation at a mean follow-up of 305 days.
Synapse has enriched 10 related papers. Consider them for comparative context: