Key result
Unilateral thoracoscopic ablation for stand-alone AF showed a gradual decline in efficacy, with arrhythmia-free survival rates of 50% at 6 months and 10.8% at 60 months.
Why the study?
Does unilateral thoracoscopic ablation using microwave or monopolar radiofrequency improve arrhythmia-free survival in patients with drug-resistant stand-alone atrial fibrillation?
Observational (n=38)
Does unilateral thoracoscopic ablation using microwave or monopolar radiofrequency improve arrhythmia-free survival in patients with drug-resistant stand-alone atrial fibrillation?
Unilateral thoracoscopic AF ablation using microwave or monopolar radiofrequency devices showed a gradual decline in arrhythmia-free survival over long-term follow-up, yielding unsatisfactory results.
Answers are grounded in this paper and cite their sources.
Caution warranted for long-term stand-alone AF ablation; leaves open need for RCTs on thoracoscopic durability.
OBJECTIVES: Minimally invasive surgery for atrial fibrillation (AF) has rapidly evolved recently. The long-term efficacy of most of these procedures is poorly known. METHODS: Between 2006 and 2010, 38 drug-resistant, symptomatic patients with stand-alone AF underwent unilateral, thoracoscopic, off-pump ablation. The mean age was 60 ± 8.2 (range 42-75) years and the mean AF duration was 46 ± 62 (range 3-240) months. Sixteen patients (42%) had paroxysmal, 9 (24%) had persistent and 13 (34%) had long-standing persistent AF. A box lesion was created using a microwave (26 patients) or monopolar radiofrequency (12 patients) system. Patients were prospectively followed with repeat electrocardiograms (ECGs) and ECG Holters. Additional catheter ablation was offered to patients with recurrence of arrhythmia. RESULTS: All procedures were completed as planned with one conversion to sternotomy, zero mortality and minimal in-hospital complications. The mean follow-up duration was 70 ± 19 (range 20-88) months. Arrhythmia-free survival rates after the procedure were 50, 44.4, 24.1 and 10.8% at 6, 12, 36 and 60 months, respectively, with most recurrences in the first 6 months. Twelve patients underwent additional catheter ablation(s); from the last intervention, 75% of them were in sinus rhythm (SR) with a mean follow-up of 31 ± 23 (range 4-86) months. Overall, at the end of follow-up, only 3 patients were still in SR without any arrhythmia recurrence. Major complications (cerebral, peripheral embolism or bleeding) occurred in 5 patients. CONCLUSIONS: Unilateral, thoracoscopic AF ablation is safe and technically feasible. However, the results of the microwave and monopolar radiofrequency devices were less than satisfactory, with a gradual decline in arrhythmia-free survival over a very long-term follow-up.
No takes yet. Share an insight, caveat, or question.
Straka et al. (2016) conducted an observational in Stand-alone atrial fibrillation (n=38). Unilateral, thoracoscopic, off-pump ablation using a microwave or monopolar radiofrequency system was evaluated on Arrhythmia-free survival at 60 months. Unilateral thoracoscopic ablation for stand-alone AF showed a gradual decline in efficacy, with arrhythmia-free survival rates of 50% at 6 months and 10.8% at 60 months.
Synapse has enriched 10 related papers. Consider them for comparative context: