Why the study?
Does MIQuant software provide reliable and faster infarct size assessment compared to manual planimetry in mouse models of cardiac ischemia?
Population
Mice subject to permanent coronary artery ligation (model of chronic infarcts)
Comparison
MIQuant semi-automated software tool for infarct… vs Manual planimetry
Design
Preclinical
Authors
Loading...
May expedite standardized infarct quantification in rodent models; leaves open clinical translation pending human validation.
Does MIQuant software provide reliable and faster infarct size assessment compared to manual planimetry in mouse models of cardiac ischemia?
MIQuant is a reliable, time-saving, semi-automated software tool for standardizing infarct size quantification in preclinical models of cardiac ischemia.
Nascimento et al. (2011) studied this question.