Key result
Provided text contains no clinical data and consists solely of editorial board information.
Why the study?
No sensitive, widely available, rapid turnaround assays exist to measure the anticoagulant effect of direct oral anticoagulants.
Does the ClotChek point-of-care coagulometer accurately identify meaningful anticoagulation in patients taking apixaban or rivaroxaban?
Does the ClotChek point-of-care coagulometer accurately identify meaningful anticoagulation in patients taking apixaban or rivaroxaban?
The ClotChek point-of-care coagulometer demonstrates high sensitivity and specificity for detecting meaningful anticoagulation levels in patients taking apixaban or rivaroxaban.
ClotChek may enable rapid DOAC effect assessment; leaves open whether it improves outcomes or warrants clinical adoption.
Currently, no sensitive, widely available, rapid turnaround assays to measure the effect on coagulation of direct oral anticoagulants exist. The point-of-care ClotChek (Perosphere Technologies Inc.) coagulometer was developed to address this unmet need with high sensitivity and precision. This proof-of-concept study aimed to determine normal clotting time in healthy, non-anticoagulated subjects; summarize clotting times at trough and peak drug concentrations in patients taking apixaban and rivaroxaban; and identify cut-points that maximize both sensitivity and specificity for predicting whether an individual is meaningfully anticoagulated. In 141 normal subjects, the mean clotting time was 244.2±25.8 seconds (median 244.0 sec; range 183–296 sec). In 39 patients on apixaban, mean clotting times were 293.9±32.5 seconds at trough and 323.1±27.9 seconds at peak. In 42 patients on rivaroxaban, mean clotting times were 287.8±44.9 seconds at trough and 380.4±41.2 seconds at peak. Strong positive correlations are seen between the anticoagulant drug response determined by the assay and anticoagulant drug levels for apixaban (Spearman’s rho = 0.74, p<0.0001) and for rivaroxaban (Spearman’s rho = 0.82, p<0.0001). ClotChek clotting times showed good sensitivity and specificity to identify meaningful anticoagulation (> 75 ng/ml) among patients taking apixaban (AUC=0.91, 83% sensitivity, 86% specificity) or rivaroxaban (AUC=0.96, 91% sensitivity, 90% specificity). Similar results were seen using the lower threshold of > 30 ng/ml. These results require clinical validation in further studies but suggest that the ClotChek assay could aid physicians at the point of care in making therapeutic decisions in patients with adverse events associated with oral factor Xa inhibitors.
No takes yet. Share an insight, caveat, or question.
Bakhru et al. (2026) studied this question. No clinical data is available in the provided text, which only contains the journal's editorial board information.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: