Key result
Mimics for TAVR demonstrated high agreement with semi-automated 3Mensio for aortic annulus area and reduced analysis time.
Why the study?
Preprocedural MSCT planning for TAVR is time-consuming and subject to interobserver variability, while previous validation studies of AI-based planning methods excluded anatomical variants or lacked prosthesis size agreement data. This study aimed to validate the new AI-driven Mimics for TAVR planning platform in clinical practice.
Does the automated AI-driven Mimics for TAVR planning platform provide accurate anatomical measurements and transcatheter valve sizing agreement while reducing analysis time compared to standard semi-automated software (3Mensio) in patients undergoing preprocedural MSCT for TAVR?
Cohort (n=126)
No
Does the automated AI-driven Mimics for TAVR planning platform provide accurate anatomical measurements and transcatheter valve sizing agreement while reducing analysis time compared to standard semi-automated software (3Mensio) in patients undergoing preprocedural MSCT for TAVR?
The AI-driven Mimics for TAVR platform provides highly accurate automated pre-TAVR CT measurements and 87%-90% prosthesis sizing agreement across both standard and complex anatomies while reducing planning time by over 8 minutes per case compared to semi-automated software.
Answers are grounded in this paper and cite their sources.
May expedite pre-TAVR CT workflows; leaves open prospective validation of sizing accuracy and outcomes.
BACKGROUND: Preprocedural planning with multislice computed tomography (MSCT) is an essential prerequisite for successful transcatheter aortic valve replacement (TAVR). However, preprocedural planning is time-consuming and may contain clinically meaningful interobserver variability. Artificial intelligence (AI) based automated planning methods may provide anatomical MSCT measurements while reducing the time load required for the analysis. Previous studies on the validation of AI-based TAVR planning methods excluded anatomical variants or lacked data on actual TAVR prosthesis size agreement. Mimics for TAVR (Materialise, Leuven, Belgium) is a new, AI-driven TAVR planning platform based on patient-specific 3D anatomical models and automated measurements through a web-based user interface. AIMS: To validate the Mimics for TAVR planning tool in clinical practice. METHODS: Key planning assessments were performed on pre-TAVR MSCT datasets using Mimics for TAVR and a commercially available semi-automated software package. Agreement between the two planning methods was assessed using intraclass correlation coefficients and Bland-Altman plots. RESULTS: A total of 126 consecutive patients (mean age 80 [74-85]; 56% male) who underwent MSCT as part of their TAVR work-up were included. Mimics for TAVR derived measurements showcased high accuracy and excellent agreement for the area of the aortic annulus (mean error ± SD: -1.9 ± 3.3%, ICC: 0.976 [95% CI: 0.966-0.984]), left ventricular outflow (-2.7 ± 3.8%, ICC: 0.970 [0.957-0.983]), sinotubular junction (-2.6 ± 4.2%, ICC: 0.953 [0.921-0.971]), coronary heights (LCA -3.5 ± 4.8%, ICC: 0.900 (0.859-0.928). RCA -3.9 ± 4.7%, ICC: 0.928 [0.898-0.949]) and membranous septum length (-5.0 ± 9.2%, ICC: 0.919 [0.880-0.940]). Mimics for TAVR assessment significantly reduced the time required for pre-TAVR analysis (1.03 ± 0.15 min vs. 9.55 ± 3.16 min per case, respectively (p = 0.001). CONCLUSION: The automated AI-driven Mimics for TAVR planner is an accurate alternative to existing semiautomated TAVR planning platforms and may enhance overall workflow efficiency.
No takes yet. Share an insight, caveat, or question.
Dorpel et al. (2026) conducted a cohort in Severe aortic stenosis undergoing preprocedural MSCT screening for TAVR (n=126). Mimics for TAVR (automated AI-driven TAVR planning platform) vs. 3Mensio version 10 (standard semi-automated TAVR planning software package) was evaluated on Aortic annulus area measurement accuracy and agreement (MD -9.4 mm2 (ICC 0.976), 95% CI 0.966-0.984). Mimics for TAVR demonstrated high agreement with semi-automated 3Mensio for aortic annulus area and reduced analysis time.
Synapse has enriched 10 related papers. Consider them for comparative context: