This is the authors' abstract. We don't add key points for this paper.
For the demand of high reliability in the aerospace field, multi-phase electric machines have become a research hotspot for the fault-tolerant ability. Inter-turn short-circuit fault is one of the main fault forms in the electric machine. The fault mechanism, diagnosis method and fault-tolerant control strategy of inter-turn short-circuit fault of the open-winding five-phase permanent-magnet synchronous machine that is used as the starter/generator system are studied in this paper. Firstly, the fault mechanism of the inter-turn short-circuit fault (ITSCF) is analyzed. The characteristics of phase voltage, inter-turn short-circuit current and torque ripple are compared using the phase winding open-circuit method and the phase winding short-circuit method. Secondly, a fault diagnosis method based on the information fusion is proposed, which determines the fault phase firstly and then identifies the inter-turn short-circuit ratio. According to the fault mechanism, a fault-tolerant control method is proposed, in which the accurate inter-turn short-circuit ratio and inter-turn short-circuit current are not required. The proposed fault-tolerant control method has similar torque ripple compared with the control method using accurate inter-turn short-circuit ratio and inter-turn short-circuit current. Finally, the effectiveness of the proposed fault-tolerant control method has been verified by experimental results.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: