Key result
Cardiac resynchronizer implantation improved left ventricular ejection fraction from 31% to 40% at 6 months in patients with advanced heart failure.
Why the study?
Does implantation of a cardiac resynchronizer improve left ventricular function in patients with advanced heart failure and interventricular dyssynchrony?
Observational (n=24)
Does implantation of a cardiac resynchronizer improve left ventricular function in patients with advanced heart failure and interventricular dyssynchrony?
Cardiac resynchronization therapy significantly improves left ventricular dimensions and ejection fraction at 6 months in patients with advanced heart failure and dyssynchrony.
Answers are grounded in this paper and cite their sources.
May support CRT in advanced HF with dyssynchrony; leaves open randomized confirmation before practice change.
BACKGROUND: The gold standard surgical treatment for heart failure is cardiac transplantation, however, due to difficulties of this treatment, other surgical proposals have been reported, including the implantation of cardiac resynchronizer. OBJECTIVE: To analyze the left ventricular function by echocardiography in patients with advanced heart failure with interventricular dyssynchrony undergone implantation of cardiac resynchronizer. METHODS: Between June 2006 and June 2012, 24 patients with average age of 61.5 ± 11 years were evaluated, carriers of advanced congestive heart failure functional class III and IV (NYHA), interventricular dyssynchrony and optimal drug therapy, and submitted implantation of cardiac resynchronizer and postoperative echocardiographically evaluated in six months. RESULTS: There was significant improvement of the analyzed echocardiography parameters. The average left ventricular diastolic diameter decreased from 69.6 ± 9.8 mm to 66.8 ± 8.8 mm, systolic diameters from 58.6 ± 8.8 mm to 52.7 ± 8.8 mm, and ejection fraction, average of 31 ± 8% to 40 ± 7% with level of significance, respectively, of 0.019, 0.0004 and 0.0002, statistically significant with a significance level of 0.05. CONCLUSION: There was a significant improvement of left ventricular function analyzed by echocardiography at six months, in patients with advanced heart failure undergone implantation of cardiac resynchronizer.
No takes yet. Share an insight, caveat, or question.
Benfatti et al. (2013) conducted an observational in Advanced congestive heart failure (n=24). Cardiac resynchronizer implantation vs. Baseline (pre-implantation) was evaluated on Left ventricular function by echocardiography (diastolic diameter, systolic diameter, and ejection fraction) (p=0.019, 0.0004, 0.0002). Cardiac resynchronizer implantation improved left ventricular ejection fraction from 31% to 40% at 6 months in patients with advanced heart failure.