Why the study?
How do the Hancock porcine bioprosthesis, Björk-Shiley spherical disc prosthesis, and Lillehei-Kaster tilting disc prosthesis compare in long-term outcomes for isolated mitral valve replacement?
How do the Hancock porcine bioprosthesis, Björk-Shiley spherical disc prosthesis, and Lillehei-Kaster tilting disc prosthesis compare in long-term outcomes for isolated mitral valve replacement?
Mechanical prostheses offer better long-term durability and freedom from reoperation compared to porcine bioprostheses in the mitral position, though at the cost of increased hemorrhagic complications.
May inform mitral prosthesis selection balancing durability and bleeding risk; leaves open applicability to contemporary valves and randomized confirmation.
The performance of the standard Hancock porcine bioprosthesis (HPB), the Björk-Shiley spherical disc prosthesis (BSP) and the Lillehei-Kaster tilting disc prosthesis (LKP) was compared over a 15-year follow-up in patients who underwent isolated mitral valve replacement (502 HPB, 183 LKP and 119 BSP). The cumulative duration of follow-up is 3,488 patient-years (mean, 8.0 +/- 3.7 years) for patients with a HPB, 1,302 patient-years (mean, 8.4 +/- 4.9 years) for patients with a LKP and 718 patient-years (mean, 7.1 +/- 5.6 years) for those with a BSP. At 15 years a significant difference was found among the 3 groups in freedom from (1) anticoagulant-related haemorrhages, between HPB (83% +/- 7%) and BSP (65% +/- 8%) recipients (P less than 0.05); (2) prosthetic dysfunction, BSP (96% +/- 3%) and LKP (83% +/- 6%) versus HPB (42% +/- 5%) recipients (P less than 0.001); (3) overall reoperations, BSP (94% +/- 3%) and LKP (89% +/- 3%) versus HPB (40% +/- 5%) recipients (P less than 0.001) and (4) prosthetic failure, BSP (88% +/- 4%) and LKP (71% +/- 6%) versus HPB (38% +/- 5%) recipients (P less than 0.001). No difference was found in actuarial survival, freedom from thromboembolic episodes, treatment failure and overall prosthesis-related complications. Our results confirm that the long-term performance of the HPB in the mitral position is adversely affected by the high incidence of tissue degeneration while haemorrhagic complications may limit the advantage of the longer durability of mechanical prostheses.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Milano et al. (1989) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: