What are the long-term clinical outcomes and structural durability of the standard Hancock porcine bioprosthesis?
The standard Hancock porcine bioprosthesis demonstrates excellent performance in the first 10 years, but structural valve deterioration becomes unacceptably high thereafter.
We have reviewed 665 patients in whom the standard Hancock porcine bioprosthesis (HPB) was used for aortic (AVR = 173), mitral (MVR = 437), and mitral and aortic (MAVR = 55) valve replacement in the time interval from 1970 to 1983. After AVR, HPB-related deaths occurred in 24 patients (1.7% ± 0.4% per patient-year); 11 had thromboembolic episodes (0.8% ± 0.2% per patient-year), 6 hemorrhages related to anticoagulants (0.4% ± 0.2% per patient-year), 9 endocarditis (0.7% ± 0.2% per patient-year), 7 prosthetic leak (0.5% ± 0.1 % per patient-year), and 59 structural deterioration (4.3% ± 0.6% per patient-year). At 16 years, actuarial survival is 40% ± 6%, freedom from thromboembolic episodes 89% ± 4%, from hemorrhages 90% ± 5%, from endocarditis 94% ± 2%, from prosthetic leak 95% ± 2%, and from structural deterioration 36% ± 6%. After MVR, HPB-related deaths occurred in 64 patients (1.6% ± 0.2% per patient-year); 68 had thromboembolic episodes (1.7% ± 0.2% per patient-year), 28 hemorrhages (0.7% ± 0.1% per patient-year), 12 endocarditis (0.3% ± 0.1% per patient-year), 9 prosthetic leak (0.2% ± 0.1% per patient-year), and 158 structural deterioration (4.0% ± 0.3% per patient-year). At 18 years, actuarial survival is 33% ± 4%, freedom from thromboembolic episodes 57% ± 13%, from hemorrhages 81% ± 6%, from endocarditis 91% ± 4%, from prosthetic leak 98% ± 1%, and from structural deterioration 18% ± 5%. After MAVR there were 18 HPB-related deaths (5.0% ± 1.3% per patient-year); 6 patients had thromboembolic episodes (1.7% ± 0.2% per patient-year), 6 hemorrhages (1.7% ± 0.2% per patient-year), 11 endocarditis (3.1% ± 1.1% per patient-year), 6 prosthetic leak (1.7% ± 0.7% per patient-year), and 17 structural deterioration (4.8% ± 1.2% per patient-year). At 14 years, actuarial survival is 26% ± 7%, freedom from thromboembolic episodes 85% ± 7%, from hemorrhages 80% ± 11%, from endocarditis 74% ± 7%, from prosthetic leak 93% ± 4%, and from structural deterioration 16% ± 10%. The HPB has shown excellent performance in the first decade that, however, becomes unacceptable thereafter due to the progressively increasing incidence of structural valve deterioration.
Bortolotti et al. (Sun,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: