Key result
Cardiologist radiation exposure during cardiac resynchronisation therapy implantation was 9-fold greater than during procedures without CRT.
Why the study?
Cardiologists face high ionizing radiation exposure, but no recent study had quantified operator overexposure during CRT procedures compared to classical PM or ICD implantations.
Does cardiac resynchronisation therapy (CRT) implantation increase operator radiation exposure compared to classical pacemaker or ICD implantation?
Observational (n=169)
No
Does cardiac resynchronisation therapy (CRT) implantation increase operator radiation exposure compared to classical pacemaker or ICD implantation?
Cardiologists face a 9-fold higher radiation exposure during CRT implantations compared to standard PM/ICD procedures, highlighting the need for enhanced radiation protection.
Answers are grounded in this paper and cite their sources.
CRT implantation may increase operator radiation exposure; leaves open whether shielding protocols meaningfully reduce long-term risks.
Cardiologists are among the health professionals that are most exposed to ionizing radiation, but there is no recent study quantifying overexposure of physicians during cardiac resynchronisation therapy (CRT) procedures compared to ‘classical’ implantation of pacemakers (PMs) or implantable cardioverter-defibrillators (ICDs). We aimed to measure and compare operator exposure to radiation during implantation of PM and ICD with or without CRT. The study population comprised all PMs and ICDs implanted in a large referral centre over a six months period. The endpoint was operator radiation exposure, assessed using a personal electronic dosimeter located on operator’s chest. In total, 169 PM/ICD implantations were analysed, 19 of which included CRT. Compared with ‘classical’ implantation, cardiologist radiation exposure was 9-fold greater during CRT procedures (p < 0.001). Physician exposure was related to dose-area product (R 2 = 0.21 during ‘classical’ implantations and R 2 = 0.57 during CRT procedures). Our study shows that cardiologists’ exposure to radiation during CRT implantation was 9-fold greater than during procedures without CRT.
No takes yet. Share an insight, caveat, or question.
Daval et al. (2019) conducted an observational in Pacemaker and implantable cardioverter-defibrillator implantation (n=169). Cardiac resynchronisation therapy (CRT) implantation vs. Implantation of pacemakers and implantable cardioverter-defibrillators without CRT was evaluated on Operator radiation exposure (9-fold greater, p=<0.001). Cardiologist radiation exposure during cardiac resynchronisation therapy implantation was 9-fold greater than during procedures without CRT.
Synapse has enriched 10 related papers. Consider them for comparative context: