Why the study?
Visual blood loss estimation and vital signs underestimate postpartum hemorrhage and delay detection, creating a need for quantitative monitoring of compensatory peripheral vasoconstriction as an early alert.
Does a wearable laser speckle flow index (LSFI) sensor accurately detect hemorrhage-induced peripheral vasoconstriction compared to standard vital signs in a swine model?
Does a wearable laser speckle flow index (LSFI) sensor accurately detect hemorrhage-induced peripheral vasoconstriction compared to standard vital signs in a swine model?
Answers are grounded in this paper and cite their sources.
A low-cost, wearable laser speckle flow index sensor accurately detects early peripheral vasoconstriction during hemorrhage in a swine model, outperforming standard vital signs like the shock index.
Postpartum hemorrhage (PPH) is both the leading and most preventable cause of maternal mortality. PPH is currently diagnosed through visual estimation of blood loss or vital sign analysis of shock index (ratio of heart rate to systolic blood pressure). Visual assessment underestimates blood loss, particularly in the setting of internal bleeding, and compensatory mechanisms stabilize hemodynamics until hemorrhage is massive, beyond the point of pharmaceutical intervention. Quantitative monitoring of hemorrhage-induced compensatory processes, such as the constriction of peripheral vessels to shunt blood to the central organs, may provide an early alert for PPH. To this end, we developed a low-cost, wearable optical device that continuously monitors peripheral perfusion via laser speckle flow index (LSFI) to detect hemorrhage-induced peripheral vasoconstriction. The device was first tested using flow phantoms across a range of physiologically relevant flow rates and demonstrated a linear response. Subsequent testing occurred in swine hemorrhage studies (n=6) by placing the device on the posterior side of the swine's front hock and withdrawing blood from the femoral vein at a constant rate. Resuscitation with intravenous crystalloids followed the induced hemorrhage. The mean LSFI vs. percent estimated blood volume loss had an average correlation coefficient of -0.95 during the hemorrhage phase and 0.79 during resuscitation, both of which were superior to the performance of the shock index. With continued development, this noninvasive, low-cost, and reusable device has global potential to provide an early alert of PPH when low-cost and accessible management strategies are most effective, helping to reduce maternal morbidity and mortality from this largely preventable problem.
No takes yet. Share an insight, caveat, or question.
Bonetta-Misteli et al. (2023) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: