Why the study?
Does stentless aortic valve replacement improve early regional LV mass regression and function compared to stented valves in patients undergoing aortic valve replacement?
Does stentless aortic valve replacement improve early regional LV mass regression and function compared to stented valves in patients undergoing aortic valve replacement?
Stentless aortic valve replacement is associated with earlier regional LV mass regression (septal thickness reduction) at 1 month compared to stented valves, though without early changes in regional systolic function.
Stentless valves accelerate early septal mass regression post-AVR without systolic gains; extends differential remodeling evidence from RCTs.
Early regional performance and hypertrophy regression after stentless aortic valve replacement are still incompletely characterized. We compared early postoperative changes of segmental thickness and function after stentless and stented aortic valve replacement as assessed by cardiac magnetic resonance (CMR). In 16 patients randomly assigned to stented (Mosaic, 8 patients) and stentless (Freestyle, 8 patients) groups, 4 parallel short-axis images at the level of the apex (slice 4), midventricle (slices 2-3), and mitral valve (slice 1) were obtained with a 1.5 T CMR scanner (Magnetom Sonata, Siemens) before and 1 month after surgery. Cine images were obtained using an echo gradient sequence. Left ventricle mass was calculated as the difference between the left ventricular end-diastolic volume at the epicardial and endocardial borders multiplied by a myocardium density factor (1.05). Each slice was divided into 8 segments (octants) from anterior (octant I-II) to septal (octant V-VIII). A total of 32 segments encompassed the entire heart. From each of these elements end diastolic thickness and systolic function (fractional thickening) were calculated. In stentless valves significant reduction of septal octant thickness on the midventricular slice was noted. There was no difference in regional systolic function-segment thickening. In stented valves no segmental thickness changes were observed. In stentless valves there was early postoperative thickness reduction of septal segments at the midventricular level. However, this finding did not coincide with changes in segmental function.
No takes yet. Share an insight, caveat, or question.
Jasiński et al. (2004) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: