Does simultaneous invasive pressure monitoring and phase-contrast magnetic resonance flow provide a feasible alternative to the Fick principle for quantifying pulmonary vascular resistance in patients with suspected pulmonary hypertension or congenital heart disease?
Does simultaneous invasive pressure monitoring and phase-contrast magnetic resonance flow provide a feasible alternative to the Fick principle for quantifying pulmonary vascular resistance in patients with suspected pulmonary hypertension or congenital heart disease?
Answers are grounded in this paper and cite their sources.
Simultaneous invasive pressure measurement and MR flow data is a feasible and safe method to measure PVR in humans, though agreement with the Fick method worsens under vasodilator testing.
BACKGROUND: Pulmonary vascular resistance (PVR) quantification is important in the treatment of children with pulmonary hypertension. The Fick principle, used to quantify pulmonary artery flow, may be a flawed technique. We describe a novel method of PVR quantification by the use of magnetic resonance (MR) flow data and invasive pressure measurements. METHODS AND RESULTS: In 24 patients with either suspected pulmonary hypertension or congenital heart disease requiring preoperative assessment, PVR was calculated by the use of simultaneously acquired MR flow and invasive pressure measurements (condition 1). In 19 of the 24 patients, PVR was also calculated at 20 ppm nitric oxide +30% (condition 2) and at 20 ppm nitric oxide +100% oxygen (condition 3), with the use of the MR method. This method proved safe and feasible in all patients. In 15 of 19 patients, PVR calculated by Fick flow was compared with the MR method. At condition 1, Bland-Altman analysis revealed a bias of 2.3% (MR > Fick) and limits of agreement of 50.2% to -45.5%. At condition 2, there was poorer agreement (bias was 28%, and the limits of agreement were 151.3% to 95.2%). At condition 3, there was very poor agreement (bias was 54.2%, and the limits of agreement were 174.4% to -66.0%). CONCLUSIONS: We have demonstrated the feasibility of using simultaneous invasive pressure measurements and MR flow data to measure PVR in humans.
No takes yet. Share an insight, caveat, or question.
Muthurangu et al. (2004) studied this question.