Why the study?
Studies comparing the impact of TAVR versus SAVR by annular size were limited.
Does transcatheter aortic valve replacement lead to similar outcomes compared to surgical aortic valve replacement in low-risk patients with severe aortic stenosis irrespective of annular size?
Does transcatheter aortic valve replacement lead to similar outcomes compared to surgical aortic valve replacement in low-risk patients with severe aortic stenosis irrespective of annular size?
TAVR provides similar 5-year clinical and health status outcomes compared to SAVR in low-risk patients with severe aortic stenosis, regardless of aortic annulus size.
Answers are grounded in this paper and cite their sources.
Similar 5-year TAVR and SAVR outcomes across annular sizes support valve choice in low-risk AS; extends PARTNER 3 without size interaction.
BACKGROUND: There are limited studies comparing the impact of transcatheter aortic valve replacement (TAVR) vs surgical aortic valve replacement (SAVR) by annular size. OBJECTIVES: The aim of this post hoc analysis from the PARTNER (Placement of Aortic Transcatheter Valves) 3 trial was to assess the relationship between annular size and outcomes among patients with severe aortic stenosis (AS) who underwent TAVR or SAVR. METHODS: ). The primary endpoint was the composite of death, stroke, or rehospitalization. Interactions among annular size, treatment strategy, and adjudicated 5-year clinical outcomes were assessed. RESULTS: Of the 925 patients with available computed tomographic angiography-derived annular size, 293 had small and 632 had large aortic annuli, respectively. Median follow-up duration was 5.2 years (Q1-Q3: 5.0-6.0 years). Five-year rates of the primary endpoint were similar for TAVR and SAVR in the overall cohort, results that were consistent for patients with small (21.2% vs 31.0%; OR: 0.60; 95% CI: 0.35-1.02) and large (23.5% vs 25.5%; OR: 0.90; 95% CI: 0.62-1.29) annuli, without effect modification by annular size (P for interaction = 0.22). Rates of bioprosthetic valve failure were similar and low at 5 years, without effect modification by annular size. Five-year health status was also similar between treatment modalities across annulus strata (P for interaction = 0.12). CONCLUSIONS: TAVR with the SAPIEN 3 valve led to similar 5-year clinical and health status outcomes compared with SAVR, irrespective of annular size. (PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [P3]; NCT02675114).
No takes yet. Share an insight, caveat, or question.
Madhavan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: