Why the study?
Does noninvasive transthoracic bio-impedance improve the prediction of heart failure decompensation compared to daily weight monitoring in patients with chronic heart failure?
Does noninvasive transthoracic bio-impedance improve the prediction of heart failure decompensation compared to daily weight monitoring in patients with chronic heart failure?
Noninvasive transthoracic bio-impedance combined with trend algorithms significantly improves the sensitivity of detecting heart failure decompensation compared to standard daily weight monitoring, though it may generate false alerts.
Answers are grounded in this paper and cite their sources.
Trend algorithms with transthoracic bioimpedance may improve early HF decompensation detection; leaves open prospective validation before clinical adoption.
BACKGROUND: Heart Failure (HF) is a common reason for hospitalization. Admissions might be prevented by early detection of and intervention for decompensation. Conventionally, changes in weight, a possible measure of fluid accumulation, have been used to detect deterioration. Transthoracic impedance may be a more sensitive and accurate measure of fluid accumulation. OBJECTIVE: In this study, we review previously proposed predictive algorithms using body weight and noninvasive transthoracic bio-impedance (NITTI) to predict HF decompensations. METHODS: We monitored 91 patients with chronic HF for an average of 10 months using a weight scale and a wearable bio-impedance vest. Three algorithms were tested using either simple rule-of-thumb differences (RoT), moving averages (MACD), or cumulative sums (CUSUM). RESULTS: Algorithms using NITTI in the 2 weeks preceding decompensation predicted events (P<.001); however, using weight alone did not. Cross-validation showed that NITTI improved sensitivity of all algorithms tested and that trend algorithms provided the best performance for either measurement (Weight-MACD: 33%, NITTI-CUSUM: 60%) in contrast to the simpler rules-of-thumb (Weight-RoT: 20%, NITTI-RoT: 33%) as proposed in HF guidelines. CONCLUSIONS: NITTI measurements decrease before decompensations, and combined with trend algorithms, improve the detection of HF decompensation over current guideline rules; however, many alerts are not associated with clinically overt decompensation.
No takes yet. Share an insight, caveat, or question.
Gyllensten et al. (2016) studied this question.