Answers are grounded in this paper and cite their sources.
A comprehensive laboratory test campaign is presented evaluating the long-term performance of 69 thirteen-year-old, high-range, low-cost Indoor Environment Quality (IEQ) and comfort sensor (CO2, temperature and relative humidity-RH). These sensors, collected in mid-2020 from 15 apartments during the Performance 2 project in Paris, were assessed for their suitability in both short- and long-term IEQ monitoring and their potential integration in ventilation strategies. The study found that high-range, low-cost temperature and RH sensors are generally reliable for short- to mid-term monitoring, though their significant long-term drift should be accounted for in extended monitoring applications to maintain data accuracy. Additionally, the evaluation highlighted substantial limitations with single-beam non-dispersive infrared (NDIR) CO2 sensors for monitoring occupancy levels in residential settings. These sensors rely on regular exposure to ambient CO2 levels (400-450 ppm) to maintain calibration, making them less suitable in consistently occupied or over-occupied environments where CO2 seldom returns to baseline levels. The findings suggest that effective long-term IEQ monitoring and ventilation strategies should consider initial tolerances, environmental influences and drift in sensor accuracy over time. Moreover, the study recommends that ventilation standards incorporate these considerations for ventilation strategies to optimise IEQ, energy efficiency and public health outcomes in residential environments.
No takes yet. Share an insight, caveat, or question.
Mora et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: