Key result
Radiofrequency ablation using a new irrigated tip magnetic catheter achieved acute success in 3 of 4 patients with electrical storm due to scar-related ventricular tachycardia.
Why the study?
Does radiofrequency ablation using a new irrigated tip magnetic catheter achieve acute success in patients with electrical storm due to scar-related VT?
Case Report (n=4)
Does radiofrequency ablation using a new irrigated tip magnetic catheter achieve acute success in patients with electrical storm due to scar-related VT?
Answers are grounded in this paper and cite their sources.
Irrigated ablation of scar-related VT guided by remote MNS appears feasible and effective for managing electrical storm in ischemic cardiomyopathy with minimal radiation exposure.
BACKGROUND: A remote magnetic navigation system (MNS) has been used with a nonirrigated magnetic catheter for ablation of some supraventricular and ventricular arrhythmias. However, the irrigated tip catheter has not been evaluated. OBJECTIVE: To evaluate the feasibility and efficiency of the newly available irrigated tip magnetic catheter for radiofrequency ablation (RF) of electrical storm due to scar-related ventricular tachycardia (VT) in patients with ischemic heart disease. METHODS: Between January and March 2008, a total of 4 consecutive patients (4 men, mean age 67.7 years) with electrical storm who had an implantable cardioverter defibrillator underwent radiofrequency ablation using a remote MNS and the new magnetic irrigated catheter. RESULTS: Five ablation procedures were performed in study patients. Acute success, defined as noninducibility of any monomorphic VT, was obtained in 3 patients. In 1 patient, a nonclinical VT remained inducible. A monomorphic VT corresponding to clinical VT with the median (range) cycle length of 485 (440-580) ms was induced in all patients. The duration of ablation was 2,273 (985-3087) seconds, with median total procedure and fluoroscopy times of 135 (100-150) minutes and 6.5 (5-9) minutes, respectively. One recurrence occurred 1 week after ablation, which was ablated successfully in the second session. No complication was observed after ablation. During mean follow-up of 4.2 months, all patients were in sinus rhythm, they received no ICD therapy, and no mortality occurred. CONCLUSIONS: Irrigated ablation of scar-related ventricular tachycardia guided by remote MNS is a feasible and effective modality for management of the electrical storm in patients with ischemic cardiomyopathy with minimal radiation exposure.
No takes yet. Share an insight, caveat, or question.
Haghjoo et al. (2009) conducted a case report in Electrical storm due to scar-related ventricular tachycardia (n=4). Radiofrequency ablation using a remote magnetic navigation system and new irrigated tip magnetic catheter was evaluated on Acute success (noninducibility of any monomorphic VT). Radiofrequency ablation using a new irrigated tip magnetic catheter achieved acute success in 3 of 4 patients with electrical storm due to scar-related ventricular tachycardia.