Key result
Quiescent phases calculated from the aggregate vessel deviation signal yielded comparable diagnostic quality to CT scanner calculations, with significant improvement for the right coronary artery.
Why the study?
Does a correlation-based phase-to-phase deviation measure improve the diagnostic quality of cardiac CT reconstructions compared to standard CT scanner calculations in patients undergoing cardiac CT?
Observational (n=20)
Blinded to the source of the reconstructions
No
Does a correlation-based phase-to-phase deviation measure improve the diagnostic quality of cardiac CT reconstructions compared to standard CT scanner calculations in patients undergoing cardiac CT?
A novel correlation-based phase-to-phase deviation measure using the interventricular septum as a predictor of vessel quiescence provides comparable or improved diagnostic image quality compared to standard CT scanner algorithms.
Answers are grounded in this paper and cite their sources.
May support correlation-based phase selection in cardiac CT; hypothesis-generating pending prospective validation.
PURPOSE: Accurate knowledge of cardiac quiescence is crucial to the performance of many cardiac imaging modalities, including computed tomography coronary angiography (CTCA). To accurately quantify quiescence, a method for detecting the quiescent periods of the heart from retrospective cardiac computed tomography (CT) using a correlation-based, phase-to-phase deviation measure was developed. METHODS: Retrospective cardiac CT data were obtained from 20 patients (11 male, 9 female, 33-74 yr) and the left main, left anterior descending, left circumflex, right coronary artery (RCA), and interventricular septum (IVS) were segmented for each phase using a semiautomated technique. Cardiac motion of individual coronary vessels as well as the IVS was calculated using phase-to-phase deviation. As an easily identifiable feature, the IVS was analyzed to assess how well it predicts vessel quiescence. Finally, the diagnostic quality of the reconstructed volumes from the quiescent phases determined using the deviation measure from the vessels in aggregate and the IVS was compared to that from quiescent phases calculated by the CT scanner. Three board-certified radiologists, fellowship-trained in cardiothoracic imaging, graded the diagnostic quality of the reconstructions using a Likert response format: 1 = excellent, 2 = good, 3 = adequate, 4 = nondiagnostic. RESULTS: Systolic and diastolic quiescent periods were identified for each subject from the vessel motion calculated using the phase-to-phase deviation measure. The motion of the IVS was found to be similar to the aggregate vessel (AGG) motion. The diagnostic quality of the coronary vessels for the quiescent phases calculated from the aggregate vessel (PAGG) and IVS (PIV S) deviation signal using the proposed methods was comparable to the quiescent phases calculated by the CT scanner (PCT). The one exception was the RCA, which improved for PAGG for 18 of the 20 subjects when compared to PCT (PCT = 2.48; PAGG = 2.07, p = 0.001). CONCLUSIONS: A method for quantifying the motion of specific coronary vessels using a correlation-based, phase-to-phase deviation measure was developed and tested on 20 patients receiving cardiac CT exams. The IVS was found to be a suitable predictor of vessel quiescence. The diagnostic quality of the quiescent phases detected by the proposed methods was comparable to those calculated by the CT scanner. The ability to quantify coronary vessel quiescence from the motion of the IVS can be used to develop new CTCA gating techniques and quantify the resulting potential improvement in CTCA image quality.
No takes yet. Share an insight, caveat, or question.
Wick et al. (2015) conducted an observational in Clinical indications requiring cardiac CT (n=20). Correlation-based phase-to-phase deviation measure for cardiac quiescence (PAGG) vs. CT scanner calculated quiescent phases (PCT) was evaluated on Diagnostic quality score of the right coronary artery (1=excellent to 4=nondiagnostic) (p=0.001). Quiescent phases calculated from the aggregate vessel deviation signal yielded comparable diagnostic quality to CT scanner calculations, with significant improvement for the right coronary artery.
Synapse has enriched 10 related papers. Consider them for comparative context: