Why the study?
Does the ratio of left ventricular isovolumetric contraction to ejection times correlate with stroke volume in humans and dogs?
Does the ratio of left ventricular isovolumetric contraction to ejection times correlate with stroke volume in humans and dogs?
The ratio of left ventricular isovolumetric contraction to ejection times provides a highly significant estimation of stroke volume.
May support noninvasive stroke volume estimation; leaves open prospective validation before clinical use.
Examination was made of the relationship of left ventricular isovolumetric contraction and ejection times to stroke volume. These studies were performed in humans at cardiac catheterization using the dye dilution technique and in open-chest dogs with electromagnetic flowmeters. The cardiac phases were measured from intracardiac catheters in humans and were calculated from the flow curves in dogs. While the isovolumetric and ejection periods independently gave correlations of only marginal significance with stroke volume, the ratio of these intervals was highly significant: r=0.92 for humans and r=0.86 for dogs.
No takes yet. Share an insight, caveat, or question.
Agress et al. (1968) studied this question.