Key result
Surgical repair of functional tricuspid regurgitation using a rigid or semirigid annular ring provides superior durability compared with suture and flexible band techniques.
Why the study?
Does surgical repair with a rigid or semirigid annular ring improve durability compared to suture and flexible band techniques in patients with functional tricuspid regurgitation?
Does surgical repair with a rigid or semirigid annular ring improve durability compared to suture and flexible band techniques in patients with functional tricuspid regurgitation?
Rigid or semirigid ring annuloplasty is recommended for functional tricuspid regurgitation to provide superior durability over suture or flexible band techniques.
May support rigid/semirigid rings for durable functional TR repair; leaves open randomized confirmation.
Functional tricuspid regurgitation (TR) primarily arises from asymmetric dilation of the tricuspid annulus in the setting of right ventricular dysfunction and enlargement in response to left-sided myocardial and valvular abnormalities. Even if the TR is not severe at the time of mitral valve surgery, it can worsen and even appear late after successful mitral valve surgery, which portends a poor prognosis. Despite data demonstrating inferior outcomes in the presence of residual TR, surgical repair for functional TR remains underused. Acceptance of TR, in the presence of tricuspid annular dilation, may be unacceptable. Surgical repair should consist of placement of a rigid or semirigid annular ring, which has been shown to provide superior durability as compared with suture and flexible band techniques. Finally, percutaneous annuloplasty for correction of functional TR may allow treatment of patients with recurrent TR at high risk of reoperation.
No takes yet. Share an insight, caveat, or question.
Weir et al. (2018) conducted a review in Functional tricuspid regurgitation. Surgical repair with rigid or semirigid annular ring vs. Suture and flexible band techniques was evaluated. Surgical repair of functional tricuspid regurgitation using a rigid or semirigid annular ring provides superior durability compared with suture and flexible band techniques.