Key result
A novel 3D cardiovascular magnetic resonance algorithm was feasible and accurate for the dynamic assessment of mitral and tricuspid annuli in normal subjects and patients with valvular regurgitation.
Why the study?
Can cardiovascular magnetic resonance with 3D reconstruction accurately evaluate mitral and tricuspid valve annulus morphology and dynamics in normal and regurgitant valves?
Observational (n=22)
Can cardiovascular magnetic resonance with 3D reconstruction accurately evaluate mitral and tricuspid valve annulus morphology and dynamics in normal and regurgitant valves?
Dynamic 3D assessment of tricuspid and mitral annuli using CMR is feasible and can accurately characterize annular changes associated with valvular regurgitation, potentially aiding in surgical planning and prosthesis design.
3D CMR feasible for annular dynamics in regurgitation; hypothesis-generating, requires prospective validation before clinical adoption.
AIMS: To explore the potentiality of cardiovascular magnetic resonance (CMR) in the quantitative evaluation of mitral valve annulus (MVA) and tricuspid valve annulus (TVA) morphology and dynamics. METHODS AND RESULTS: CMR was performed in 13 normal subjects and 9 patients with mitral (n = 7) or tricuspid regurgitation (n = 2), acquiring cine-images in 18 radial long-axis planes passing through the middle of MVA or TVA. A novel algorithm was used to obtain dynamic three-dimensional (3D) reconstruction of MVA and TVA. Analysis was feasible in all cases, allowing accurate 3D annular reconstruction and tracking. The 3D area increased from systole [MVA, median = 10.0 cm(2) (first quartile = 8.6, third quartile = 11.4); TVA, 11.2 cm(2) (8.8-13.2)] to diastole [MVA, 10.6 cm(2) (9.4, 11.7); TVA, 11.9 cm(2) (9.2-13.5)], with TVA larger than MVA. While the longest diameter showed similar systolic and diastolic values, the shortest diameter elongated from systole [MVA, 30 mm (29-33); TVA, 33 mm (31-36)] to diastole [MVA, 31 mm (29-32); TVA, 36 mm (33-39)]. Also, TVA became more circular than MVA. TVA showed lower peak systolic excursion in the septal [15.9 mm (13.0-18.5)] and anterior regions [17.9 mm (12.2-20.7)] compared with the posterior [21.9 mm (18.6-24.0)] segment. Values in MVA were smaller than in TVA, slightly higher in anterior [11.2 mm (9.5-13.0)] than in posterior [12.4 mm (10.2-14.6)] segments. Valvular regurgitation was associated with enlarged, flattened, and more circular annuli. CONCLUSION: The applied method was feasible and accurate in normal and regurgitant valves, and may potentially have an impact on diagnosis, improvement of surgical techniques and design of annular prostheses.
No takes yet. Share an insight, caveat, or question.
Maffessanti et al. (2013) conducted an observational in Mitral or tricuspid regurgitation and normal subjects (n=22). Cardiovascular magnetic resonance (CMR) with 3D dynamic assessment was evaluated on Quantitative evaluation of mitral valve annulus (MVA) and tricuspid valve annulus (TVA) morphology and dynamics. A novel 3D cardiovascular magnetic resonance algorithm was feasible and accurate for the dynamic assessment of mitral and tricuspid annuli in normal subjects and patients with valvular regurgitation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: