Key result
Respiration-driven cyclic FFR variations alter stenosis classification in ~21% of cases during adenosine hyperemia.
Why the study?
The study evaluated the occurrence and physiology of respiration-related beat-to-beat variations in resting Pd/Pa and FFR during intravenous adenosine administration, and their impact on clinical decision-making.
Do respiration-related beat-to-beat variations impact FFR measurements during intravenous adenosine administration?
Observational (n=37)
No
Do respiration-related beat-to-beat variations impact FFR measurements during intravenous adenosine administration?
Respiration causes clinically relevant beat-to-beat variations in FFR during adenosine hyperemia, which can lead to stenosis misclassification but is overcome by averaging FFR over five cardiac cycles.
Answers are grounded in this paper and cite their sources.
Respiratory effects may alter FFR stenosis classification during adenosine; leaves open whether cycle-averaging protocols enhance reliability.
Aims We evaluated the occurrence and physiology of respiration‐related beat‐to‐beat variations in resting Pd/Pa and FFR during intravenous adenosine administration, and its impact on clinical decision‐making. Methods and Results Coronary pressure tracings in rest and at plateau hyperemia were analyzed in a total of 39 stenosis from 37 patients, and respiratory rate was calculated with ECG‐derived respiration (EDR) in 26 stenoses from 26 patients. Beat‐to‐beat variations in FFR occurred in a cyclical fashion and were strongly correlated with respiratory rate (R 2 = 0.757, p < 0.001). There was no correlation between respiratory rate and variations in resting Pd/Pa. When single‐beat averages were used to calculate FFR, mean ΔFFR was 0.04 ± 0.02. With averaging of FFR over three or five cardiac cycles, mean ΔFFR decreased to 0.02 ± 0.02, and 0.01 ± 0.01, respectively. Using a FFR ≤ 0.80 threshold, stenosis classification changed in 20.5% (8/39), 12.8% (5/39) and 5.1% (2/39) for single‐beat, three‐beat and five‐beat averaged FFR. The impact of respiration was more pronounced in patients with pulmonary disease (ΔFFR 0.05 ± 0.02 vs 0.03 ± 0.02, p = 0.021). Conclusion Beat‐to‐beat variations in FFR during plateau hyperemia related to respiration are common, of clinically relevant magnitude, and frequently lead FFR to cross treatment thresholds. A five‐beat averaged FFR, overcomes clinically relevant impact of FFR variation.
No takes yet. Share an insight, caveat, or question.
Feenstra et al. (2021) conducted an observational in Stable coronary artery disease (n=37). Respiration during intravenous adenosine-induced hyperemia vs. Resting conditions / multi-beat (3-beat and 5-beat) FFR averaging was evaluated on Correlation between respiratory rate and cyclic beat-to-beat variations in fractional flow reserve (FFR) during hyperemia (R2 = 0.757, p=<0.001). Respiration strongly correlated with cyclic beat-to-beat FFR variations during intravenous adenosine hyperemia, altering stenosis classification in 20.5% of cases.
Synapse has enriched 10 related papers. Consider them for comparative context: