Key result
Electrochemical microsensors uniquely enable real-time in vivo vascular nitric oxide and superoxide detection.
Advancements in miniaturized electrochemical microsensors and lab-on-a-chip systems may enable simultaneous, real-time in situ measurements of nitric oxide and reactive oxygen species in the coronary circulation to directly evaluate endothelial function in cardiovascular disease.
Answers are grounded in this paper and cite their sources.
Enables direct vascular NO/superoxide assessment; leaves open clinical translation for endothelial evaluation in CVD.
Vascular generation of nitric oxide (NO) plays an important role in the regulation of blood flow, and is counterbalanced by the formation of radical oxygen species (ROS). Thus, an imbalance in vascular NO and ROS production contributes to endothelial dysfunction, which is associated with cardiovascular disease. Here we review the main and commonly used methods that have been applied to determine vascular NO and ROS. Only NO microsensors, electron spin resonance (ESR), and NO sensitive fluorescent probes allow real time measurement of NO levels in cell suspensions, cell cultures, and isolated vascular segments in vitro, and of these techniques only NO microsensors have so far been developed for real time detection of NO in vivo. ROS formation has been detected in cell cultures by lucigeninenhanced fluorescence, fluorescent probes e.g. 2’,7’-dichlorodihydrofluorescein and dihydroethidium, by use of ESR, and also by electrochemical detection. The limitations of the electrochemical microsensors include interference from other substances, physical force on the sensors, and influence of temperature and changes in pH that may lead to artifactual changes in current. Therefore, specificity testing and calibration are pivotal, and in case of ROS, application of more than one technique is recommendable. Technical advances have allowed simultaneous detection of both NO and superoxide anion by use of electrochemical microsensors. Miniaturizing the sensors may also allow incorporation of those in lab-ona- chip and may lead to real time measurements of NO and ROS in the coronary circulation in situ, and hence provide direct evaluation of endothelial and vascular function in cardiovascular disease.
No takes yet. Share an insight, caveat, or question.
Rodríguez‐Rodríguez et al. (2012) conducted a review in Endothelial dysfunction and cardiovascular disease. Analytical methods for measuring vascular nitric oxide and reactive oxygen species (electrochemical microsensors, electron spin resonance, fluorescent probes, chemiluminescence) was evaluated on Real-time and direct measurement of nitric oxide and reactive oxygen species in vascular cells and tissues. Electrochemical microsensors currently provide the only method for real-time in vivo detection of vascular nitric oxide and simultaneous detection of superoxide anion.
Synapse has enriched 10 related papers. Consider them for comparative context: