Why the study?
Automatic signal quality assessment and noise-type identification are needed to enhance wearable ECG reliability, minimize false alarms, and enable noise-specific denoising under limited computing resources.
A lightweight deep learning framework can accurately and rapidly classify ECG signal quality and noise types on resource-constrained wearable devices.
May enhance wearable ECG reliability in constrained devices; leaves open need for prospective clinical validation.
Wearable devices offer continuous monitoring of ECG signals for arrhythmia detection with limited computing resources. Automatic signal quality assessment (SQA) is crucial for enhancing the reliability of such devices and minimizing false alarms. Additionally, identifying noise types can improve the effectiveness of noise-specific denoising strategies in such limited resource-based devices. This study proposes a lightweight deep learning framework for multi-level ECG SQA and noise-type classification suitable for resource-constrained wearable monitoring devices. The model architecture with a suitable activation function is optimized through extensive comparative performance analysis. The proposed approach effectively classifies clean ECG, ECG with low-frequency noise, ECG with high-frequency noise, ECG with mixed-frequency noise, and unacceptable ECG. The test ECG segments are generated from the standard MIT-BIH arrhythmia database (MIT-BIHA), PhysioNet Challenge 2011 database (PCCC-2011), and PhysioNet Challenge 2021 dataset (PCCC-2021). The optimized model demonstrates an average F1-score of 98.05% for the MIT-BIHA. For completely unknown test datasets, the F1-score of 95.93% and 94.20% are reported for PCCC-2011 and PCCC-2021, respectively. The proposed framework is implemented on a Raspberry Pi platform to assess its feasibility in a resource-limited platform. The optimized trained model with a size of only 435 kB effectively classifies real-time ECG signal quality with an average computation time of 510.19 milliseconds on Raspberry Pi. The detailed analysis of the results confirms that the proposed approach classifies ECG signal quality and noise types in real-time on a limited computing resource-based platform which makes it well-suited for wearable ECG monitoring devices.
No takes yet. Share an insight, caveat, or question.
Rakshit et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: