Key result
Remote blood pressure estimation using a spatiotemporal mapping network achieved a mean absolute error of 12.35 mmHg for systolic BP and 9.54 mmHg for diastolic BP on the MMSE-HR dataset.
Why the study?
Blood pressure values are mainly acquired through contact-sensing methods, which are inconvenient and unfriendly for daily monitoring.
Does an end-to-end network using spatiotemporal mapping of facial videos accurately estimate blood pressure?
Does an end-to-end network using spatiotemporal mapping of facial videos accurately estimate blood pressure?
A novel end-to-end network using facial videos demonstrates potential for remote, contactless blood pressure monitoring with reasonable accuracy.
May enable remote daily BP monitoring; leaves open clinical validation before practice adoption.
Blood pressure (BP) monitoring is vital in daily healthcare, especially for cardiovascular diseases. However, BP values are mainly acquired through a contact-sensing method, which is inconvenient and unfriendly for BP monitoring. This paper proposes an efficient end-to-end network for estimating BP values from a facial video to achieve remote BP estimation in daily life. The network first derives a spatiotemporal map of a facial video. Then, it regresses the BP ranges with a designed blood pressure classifier and simultaneously calculates the specific value with a blood pressure calculator in each BP range based on the spatiotemporal map. In addition, an innovative oversampling training strategy was developed to handle the problem of unbalanced data distribution. Finally, we trained the proposed blood pressure estimation network on a private dataset, MPM-BP, and tested it on a popular public dataset, MMSE-HR. As a result, the proposed network achieved a mean absolute error (MAE) and root mean square error (RMSE) of 12.35 mmHg and 16.55 mmHg on systolic BP estimations, and those for diastolic BP were 9.54 mmHg and 12.22 mmHg, which were better than the values obtained in recent works. It can be concluded that the proposed method has excellent potential for camera-based BP monitoring in the indoor scenarios in the real world.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2023) studied Blood pressure monitoring. Remote blood pressure estimation via spatiotemporal mapping of facial videos was evaluated on Systolic and diastolic blood pressure estimation error (MAE and RMSE). Remote blood pressure estimation using a spatiotemporal mapping network achieved a mean absolute error of 12.35 mmHg for systolic BP and 9.54 mmHg for diastolic BP on the MMSE-HR dataset.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: