Key result
A nonparametric frequency-domain closed-loop identification method was demonstrated for analyzing the dynamic characteristics of the arterial baroreflex system.
Why the study?
Closed-loop negative feedback operation makes it difficult to identify open-loop dynamic characteristics of the neural and peripheral arcs in the arterial baroreflex system.
A nonparametric frequency-domain closed-loop identification method can be used to estimate the open-loop dynamic characteristics of the arterial baroreflex system in an anesthetized rabbit model.
Answers are grounded in this paper and cite their sources.
Identifies baroreflex arc dynamics in sympathetic AP control; leaves open translation to human hypertension therapies.
The arterial baroreflex system plays a key role in maintaining the homeostasis of arterial pressure (AP). Changes in AP affect autonomic nervous activities through the baroreflex neural arc, whereas changes in the autonomic nervous activities, in turn, alter AP through the baroreflex peripheral arc. This closed-loop negative feedback operation makes it difficult to identify open-loop dynamic characteristics of the neural and peripheral arcs. Regarding sympathetic AP controls, we examined the applicability of a nonparametric frequency-domain closed-loop identification method to the carotid sinus baroreflex system in anesthetized rabbits. This article compares the results of an open-loop analysis applied to open-loop data, an open-loop analysis erroneously applied to closed-loop data, and a closed-loop analysis applied to closed-loop data. To facilitate the understanding of the analytical method, sample data files and sample analytical codes were provided. In the closed-loop identification, properties of the unknown central noise that modulated the sympathetic nerve activity and the unknown peripheral noise that fluctuated AP affected the accuracy of the estimation results. A priori knowledge about the open-loop dynamic characteristics of the arterial baroreflex system may be used to advance the assessment of baroreflex function under closed-loop conditions in the future.
No takes yet. Share an insight, caveat, or question.
Kawada et al. (2021) studied this question. Closed-loop identification method vs. Open-loop analysis was evaluated. A nonparametric frequency-domain closed-loop identification method was demonstrated for analyzing the dynamic characteristics of the arterial baroreflex system.