Key result
Electrical impedance plethysmography yielded pulse wave velocity estimates in peripheral arteries that were in agreement with the gold-standard tonometer technique, demonstrating similar beat-to-beat variability.
Why the study?
Gold-standard tonometry to measure pulse wave velocity requires manual probe fixation and operator skill, whereas electrical impedance plethysmography may offer a cost-effective, miniaturizable alternative.
Does electrical impedance plethysmography (IPG) accurately measure pulse wave velocity in peripheral arteries compared to tonometry in young healthy volunteers?
Observational (n=10)
Does electrical impedance plethysmography (IPG) accurately measure pulse wave velocity in peripheral arteries compared to tonometry in young healthy volunteers?
Electrical impedance plethysmography (IPG) may be a suitable, cost-effective, and easier-to-use alternative to tonometry for estimating pulse wave velocity in peripheral arteries.
Answers are grounded in this paper and cite their sources.
IPG may offer a feasible alternative for leg PWV assessment in healthy volunteers; leaves open validation in broader populations before clinical adoption.
The leading cause of health loss and deaths worldwide are cardiovascular diseases. A predictor of cardiovascular diseases and events is the arterial stiffness. The pulse wave velocity (PWV) can be used to estimate arterial stiffness non-invasively. The tonometer is considered as the gold standard for measuring PWV. This approach requires manual probe fixation above the artery and depends on the skills of the operator. Electrical impedance plethysmography (IPG) is an interesting alternative using skin surface sensing electrodes, that is miniaturizable, cost-effective and allows measurement of deeper arteries. The aim of this pilot study was to explore if IPG can be a suitable technique to measure pulse wave velocity in legs as an alternative for the tonometer technique. The PWV was estimated by differences in the ECG-gated pulse arrival times (PAT) at the a. femoralis, a. popliteal, a. tibialis dorsalis and a. dorsalis pedis in nine healthy young adults using IPG and the SphygmoCor tonometer as a reference. The estimated PWV results from bioimpedance and the tonometer were fairly in agreement, and the beat-to-beat variability in PAT was similar. This pilot study indicates that the use of IPG may be a good alternative for estimating PWV in the legs.
No takes yet. Share an insight, caveat, or question.
Wiegerinck et al. (2021) conducted an observational in Healthy volunteers (n=10). Electrical impedance plethysmography (IPG) vs. SphygmoCor tonometer was evaluated on Agreement of pulse wave velocity (PWV) and pulse arrival time (PAT) between IPG and tonometry. Electrical impedance plethysmography yielded pulse wave velocity estimates in peripheral arteries that were in agreement with the gold-standard tonometer technique, demonstrating similar beat-to-beat variability.