Key result
In patients with hypertrophic cardiomyopathy, real-time three-dimensional ultrasonography revealed that the severity of left ventricular diastolic dyssynchrony was positively correlated with systolic dyssynchrony (r=0.413, P<0.05).
Why the study?
Can single-cardiac real-time three-dimensional ultrasonography effectively evaluate the relationship between left ventricular diastolic and systolic dyssynchrony in patients with hypertrophic cardiomyopathy?
Case-Control (n=104)
No
Can single-cardiac real-time three-dimensional ultrasonography effectively evaluate the relationship between left ventricular diastolic and systolic dyssynchrony in patients with hypertrophic cardiomyopathy?
Effect estimate: r=0.413
p-value: p=<0.05
Single-cardiac real-time three-dimensional ultrasonography demonstrates that the severity of diastolic dyssynchrony is positively correlated with systolic dyssynchrony in patients with hypertrophic cardiomyopathy.
Diastolic-systolic dyssynchrony correlation in HCM supports 3D echo evaluation; leaves open prospective validation before any clinical adoption.
The relationship between left ventricular diastolic and systolic dyssynchrony in hypertrophic cardiomyopathy (HCM) was investigated by single-cardiac real-time three-dimensional ultrasonography. A total of 52 patients with HCM were selected in Jining No. 1 People's Hospital from July 2016 to June 2017. Additionally, a total of 52 healthy people were selected to serve as the control group. All participants received real-time two- and three-dimensional ultrasonography to evaluate left ventricular morphology, function and systolic and diastolic function. The relevant parameters included left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), left ventricular ejection fraction (LVEF), end-systolic/diastolic sphericity index (ESSI/EDSI), systolic dyssynchrony index (SDI), diastolic dyssynchrony index (DDI), dispersion end systole (DISPES), diastolic dyssynchrony index-late (DDI-late) and dispersion end diastole (DISPED-late). The LVEF of observation group was significantly lower than that of the control group, while LVEDV, LVESV, E/A and E/Ea were significantly higher than those in control group (P<0.05); EDSI, DDI-late and DISPED-late were significantly higher in observation than in control group (P<0.05); ESSI, SDI and DISPES in observation were significantly higher than those in control group (P<0.05); The 16-segment time-volume curve of observation group was disordered without synchronization, while the curve of control group was regular and smooth with synchronization; Pearson's correlation analysis showed that SDI and DDI were positively correlated (P<0.05). In conclusion, three-dimensional ultrasonography can be used to effectively evaluate left ventricular diastolic and systolic dyssynchrony in HCM. The severity of diastolic is positively correlated with systolic dyssynchrony.
No takes yet. Share an insight, caveat, or question.
Xing et al. (2018) conducted a case-control in Hypertrophic cardiomyopathy (n=104). Hypertrophic cardiomyopathy vs. Healthy controls was evaluated on Correlation between systolic dyssynchrony index (SDI) and diastolic dyssynchrony index (DDI) (r=0.413, p=<0.05). In patients with hypertrophic cardiomyopathy, real-time three-dimensional ultrasonography revealed that the severity of left ventricular diastolic dyssynchrony was positively correlated with systolic dyssynchrony (r=0.413, P<0.05).