Key result
Conventional and speckle-tracking echocardiography demonstrated high feasibility (84-95%) for assessing left ventricular ejection fraction and endocardial strain in normal female Syrian hamsters.
Why the study?
The Syrian hamster is an experimental model for heart diseases, but reference values for bidimensional LVEF and myocardial strain were lacking.
Conventional and speckle-tracking echocardiography are feasible in Syrian hamsters, establishing reference intervals for future experimental cardiovascular research.
Hamster LVEF and STE measures are feasible and reproducible; leaves open standardization for disease modeling.
OBJECTIVES: This study aimed to determine feasibility, reference intervals, and reproducibility of left ventricular ejection fraction (LVEF) and speckle-tracking echocardiography (STE) in adult Syrian hamsters. BACKGROUND: Syrian hamster is an experimental model for several heart diseases. Echocardiography allows the evaluation of structure and function with bidimensional conventional techniques and STE. However, there is no data regarding reference values for bidimensional LVEF and myocardial strain in hamsters. METHODS: A total of 135 female Syrian hamsters were anesthetized and studied with a small animal dedicated echocardiography system. Echocardiography measurements were obtained from M-mode and B-mode images. Feasibility and 95% reference intervals were obtained for LVEF using three different approaches: LVEF_Teichholz (from M-mode linear measurements), LVEF_BMode (from area-length method), and LVEF_ STE (from strain), and for global longitudinal (GLS), circumferential (GCS), and radial (GRS) endocardial strain. Reproducibility was assessed as intra-class correlation coefficients. RESULTS: Feasibility of LVEF and endocardial strain was high (95% in FEVE_Teichholz, 93% in the LVEF_BMode, 84% in the LVEF_STE, 84% from PSLAX, and 80% from PSSAX). Values of LVEF_Teichholz were significantly higher than values of LVEF_BMode, and LVEF_STE-derived methods (59.0 ± 5.8, 53.8 ± 4.7, 46.3 ± 5.7, p < 0.0001). The 95% reference intervals for GLS, GCS, and GRS were respectively -13.6(-7.5;-20.4)%, -20.5 ± 3.1%, and + 34,7 ± 7.0%. Intra-class correlation coefficients were 0.49 - 0.91 for LVEF measurements, 0.73 - 0.92 for STE, with better results for LVEF_Teichholz and GLS. CONCLUSIONS: Evaluation of LVEF by several methods and STE parameters is feasible in hamsters. Reference intervals for LVEF and STE obtained for this experimental animal model can be applied at future research.
No takes yet. Share an insight, caveat, or question.
Filho et al. (2021) studied Normal Syrian hamsters (n=135). Conventional and speckle-tracking echocardiography was evaluated on Feasibility and reference intervals of LVEF and endocardial strain. Conventional and speckle-tracking echocardiography demonstrated high feasibility (84-95%) for assessing left ventricular ejection fraction and endocardial strain in normal female Syrian hamsters.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: