Why the study?
Does 99mTc-Sestamibi SPECT accurately detect myocardial viability compared to NH3/FDG PET in patients with ischemic cardiomyopathy?
Does 99mTc-Sestamibi SPECT accurately detect myocardial viability compared to NH3/FDG PET in patients with ischemic cardiomyopathy?
99mTc-Sestamibi SPECT provides an acceptable, more readily available alternative to NH3/FDG PET for delineating myocardial viability in patients with severe ischemic cardiomyopathy.
Answers are grounded in this paper and cite their sources.
SPECT may offer a practical alternative to PET for viability assessment in ischemic cardiomyopathy; leaves open need for prospective outcome validation.
OBJECTIVE: Assessment of myocardial viability by 99mTc-Sestamibi Single Photon Emission Computerized Tomography (SPECT) has been suggested as a more readily available and cheaper alternative to Positron Emission Tomography (PET) with 13N-ammonia (NH3) and 18F-fluoro-deoxy-glucose (FDG). We hypothesized that a semi-quantitative evaluation by SPECT could delineate myocardial viability with an acceptable concordance to PET. DESIGN: Fifty patients (age 57+/-7 years; ejection fraction 28 +/- 8%), with ischemic cardiomyopathy, underwent SPECT and PET imaging in random order. Viability by SPECT was defined as a defect size <50% of the segment area, or a defect representing > or =50% of the segment but with a mean activity > or =50% of peak activity. PET viability was defined as a perfusion score >2 and FDG score < or =2 (five-point scale, 0 = normal, 4 = absent activity). RESULTS: By segmental comparison to PET. SPECT yielded a sensitivity and specificity of 87% and 82% for detection of viable myocardium. The positive and negative predictive values were 96% and 58%, respectively. CONCLUSION: In patients with severe ischemic cardiomyopathy 99mTc-Sestamibi SPECT can delineate viable myocardium with an acceptable segmental concordance to NH3/FDG PET.
No takes yet. Share an insight, caveat, or question.
Anne Kaltoft, Morten Bøttcher, Niels Pet (2001) studied this question.